Compare simulation results and modify model data
Change the numerical parameters Iadvec1D from 4 to 1 and Limtyphu1D from 100 to 0 according to SOBEK 3 user manaual, section 5.10.2.10 (Parameter set for comparison with SOBEK 2, Deltares Systems, 2013).
Run a simulation with your modified SOBEK 2 model with the channel flow module only.
...
- Add a new model to the project:
- right mouse-click on the project, choose "New Model...":
- Select "Rainfall Runoff Model"
- Move it to integrated model
- Import precipitation data (a *.bui file) from your SOBEK 2 model
- Create catchments
- modify the open water property
- fill in the catchment area
- choose the appropriate Rainfall Station (corresponds to the precipitation data)
- connect the catchment to the corresponding lateral node in the water flow 1d network.
References
Deltares Systems (2013): 1D/2D modelling suite for integral water solutions / SOBEK Suite / D-Flow 1D and D-Real Time Control in Delta Shell / User manual. Version: 3.0.1.29328, 30 July 2013 Deltares: Delft, The Netherlands.
Meijer, D. (2015): Results acceptance test FLOW 1D and RTC SOBEK 3. Deltares draft report 1205718-000-DSC-0124-v1.
...