Wiki Markup |
---|
{scrollbar} |
AdjustQ
Input
- observedInstantaneousDischarge
- observedMeanDailyDischarge
- simulatedDischarge
Coefficient set
- blending steps
- errorTolerance
- maxNumberOfIterations
- iterpolationType
Output
- adjustedSimulatedDischarge
Description
AdjustQ corrects the simulated discharges by using observed instantaneous discharges and observed mean dialy discharges. The procedure is actually a combination of the
transformations AdjustQUsingInstantaneousDischarge and AdjustQUsingMeanDailyDischarge. First the simulated discharged will be corrected by using the instantaneous discharges. If not all of the mean dialy discharges are within the error tolerance the simulated discharges will also be corrected with the AdjustQUsingMeanDailyDischarge procedure. A detailed description of the configuration options in the coefficient set can be found the sections of AdjustQUsingInstantaneousDischarge and AdjustQUsingMeanDailyDischarge.