Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • chamberOfCommerceNumber: will be used to set the value of the brocom:chamberOfCommerceNumber element.
  • qualityRegime: will be used to set the brocom:qualityRegime value. Can be either IMBRO or IMBRO/A

Optional properties that can be configured:

...

  • unitOfMeasurement: optional property to set the unit of measurement. Default value is 'm'.
  • splitFiles: default false. If set to true, timeseries that have 10000 or more time steps, will be

...

  • split in files with 9999 timesteps. The BRO Portal currently doesn't support more than 9999 time steps

...

  • .

...

  • statusQualityControl: default '"goedgekeurd" allowed values are:
    "afgekeurd", "goedgekeurd", "nogNietBeoordeeld", "onbeslist", "onbekend"
  • observationType: default "reguliereMeting" allowed values are:
    "reguliereMeting", "controleMeting"
  • statusCode: default

...

  • is none  allowed values are:
    "volledigBeoordeeld", "voorlopig", "onbekend"
  • processReference: default "NEN_EN_ISO22475v2006_C11v2010" allowed values are:
    "NEN5120v1991", "NEN_EN_ISO22475v2006_C11v2010", "NEN_ISO21413v2005", "NPR_ISO.TR23211v2009", "RWSgwmon", "STOWAgwst", "vitensMeetprotocolGrondwater", "waternetMeetprocedure", "onbekend"
  • measurementInstrumentType: default "druksensor" allowed values are:
    "akoestischeSensor", "akoestischHandapparaat", "analoogPeilklokje", "druksensor", "elektronischPeilklokje", "opzetStuk", "radarsensor", "stereoDruksensor", "onbekend", "onbekendPeilklokje"
  • processType: default "

...

  • " allowed values are:
    "Algorithm", "Manual Method", "Sensor", "Simulation", "Unknown"
  • evaluationProcedure: default "oordeelDeskundige" allowed values are:
    "brabantWater2013", "eijkelkampDataValidatiev0.0.9", "oordeelDeskundige", "PMBProtocolDatakwaliteitscontroleQC2018v2.0", "RWSAATGrondwaterv1.0", "validatieprocedureEvidesWaterbedrijf", "vitensBeoordelingsprotocolGrondwater", "waternetBeoordelingsprocedure", "warecoWaterDataValidatieProtocolv20200219", "onbekend"
  • airPressureCompensationType: default

...

  • is none, allowed values are:
    "capillair", "gecorrigeerdLokaleMeting", "KNMImeting", "monitoringnetmeting", "putlocatiemeting", "onbekend"

Setting a property to an empty value "" will have the same result as omitting the property from the XML configuration.

The "onbekend" value that is listed for some properties can only be used in combination with qualityRegime IMBRO/A, which can be selected during registration of a GLD and cannot be changed afterwards.

For each exported XML file a BRO ID is required. This can either be the same as the internal locationId or (preferably) should be configured as a location attribute. In the latter case idmapping is required. The location attribute that holds the BRO ID should be mapped, using a location id function.  For example:

...