The reader is named WSCCCsv which should be configured in the general section of the import. An example import configuration is shown below:
No Format |
---|
<?xml version="1.0" encoding="UTF-8"?> <timeSeriesImportRun xmlns="http://www.wldelft.nl/fews" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.wldelft.nl/fews http://fews.wldelft.nl/schemas/version1.0/timeSeriesImportRun.xsd"> <import> <general> <importType>WSCCCsv</importType> <folder>$IMPORT_FOLDER$/WSCC</folder> <failedFolder>$IMPORT_FAILED_FOLDER$</failedFolder> <idMapId>IdImportWSCC</idMapId> <importTimeZone> <timeZoneOffset>+08:00</timeZoneOffset> </importTimeZone> </general> <timeSeriesSet> <moduleInstanceId>ImportWSCC</moduleInstanceId> <valueType>scalar</valueType> <parameterId>H.obs</parameterId> <locationSetId>WSCC_Level</locationSetId> <timeSeriesType>external historical</timeSeriesType> <timeStep unit="minute" multiplier="10"/> <readWriteMode>add originals</readWriteMode> <synchLevel>1</synchLevel> <expiryTime unit="day" multiplier="3650"/> </timeSeriesSet> </import> </timeSeriesImportRun> |
An example IdMapping file (that maps the first column of the also attached example input file) is shown below:
...
- TN stands for TagName (parameter name) which defined in the SCADA System. Also user can customise the TN which may different from the SCADA System
Example:
No Format |
---|
Date,Time,S23-USR-LEV-RES-1,Qf,S48(51)-UPP-LEV-RES-1,Qf,S46(50)-LPP-LEV-RES-1,Qf,S46(24)-MCP-LEV-RES-1,Qf
06052007,02:10,2.232906,N,8.376068,N,0.271062,F,0.039377,N
|