Purpose and use of Transformation: | This transformation can for instance be used to report discharge volume statistics on sewer spillage for each month. |
---|---|
Background and Exceptions: | The unit of the input must be m3/s. The output time step must be bigger than the input time step. All input values must be non-missings, otherwise the result will be set to missing value. In case one of the inputs is doubtful, the output flag is set to ORIGINAL_DOUBTFUL. |
...