Configuration example
To import a file placed in the import folder containing GOES data directly from the server, use the following import configuration.
Import.xml
< import >
< general >
< importType >GOES_server</ importType >
<serverUrl>https://cdadata.wcda.noaa.gov/</serverUrl> <user>username</user> <password>dummy_password</password> <relativeViewPeriod unit="day" start="-1" end="0" startOverrulable="true"/>
< idMapId >import_mapping</ idMapId >
</ general >
|
<
properties
>
<
int
key
=
"minutesOfLatestMeasurement"
value
=
"45"
/>
</
properties
>
<
< timeSeriesSet >
< moduleInstanceId >my_module_Id</ moduleInstanceId >
< valueType >scalar</ valueType >
< parameterId >H.m</ parameterId >
< locationId >Delft</ locationId >
< timeSeriesType >external historical</ timeSeriesType >
< timeStep unit = "minute" multiplier = "15" />
< readWriteMode >add originals</ readWriteMode >
</ timeSeriesSet >
</ import >
|
The imported messages always contain slots for 8 parameters, which are provided in a fixed order.
The import_mapping configuration for these 8 parameters is as follow. Note that the external names of the parameters cannot should not be changed . They correspond to the 8 different parameters in the data, in order of appearance.as they actually refer to the hardcoded parameter names. Data is requested based on the external IDs.
< idMap >
<location external="518FF43C" internal="Delft"/>
< parameter internal = "H.m" external = "Main Stage" />
< parameter internal = "SecStage" external = "Secondary Stage" />
< parameter internal = "Precipitation" external = "Rainfall" />
< parameter internal = "Temperature" external = "AirTemp" />
< parameter internal = "Humidity" external = "RH" />
< parameter internal = "InternalHumidity" external = "Internal RH" />
< parameter internal = "RepeaterBattery" external = "Repeater Battery" />
< parameter internal = "MainBattery" external = "Main Battery" />
</ idMap >
|
External ID mapping is needed if the