Code Block |
---|
<?xml version="1.0" encoding="UTF-8"?>
<timeSeriesImportRun xmlns="http://www.wldelft.nl/fews"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.wldelft.nl/fews [http://fews.wldelft.nl/schemas/version1.0/timeSeriesImportRun.xsd]">
<!-- This is an example import configuration file for importing WQ CSV data from an import directory -->
<import>
<general>
<!-- Class name of WQ CSV parser is same as UmAquo CSV parser -->
<parserClassName>nl.wldelft.webservice.umaquo.timeseriesparsers.UmAquoCsvTimeSeriesParser</parserClassName>
<!-- Path to directory containing UmAquo libraries and schemas. If omitted then the content of the umaquo-bin
can be placed in the FEWS-bin dir \-->
<binDir>%REGION_HOME%/Modules/umaquo-bin</binDir>
<!-- Directory from which CSV files are to be imported -->
<folder>$IMPORT_FOLDER$/WQ/CSV</folder>
<failedFolder>$IMPORT_FAILED_FOLDER$/WQ/CSV</failedFolder>
<backupFolder>$IMPORT_BACKUP_FOLDER$/WQ/CSV</backupFolder>
<idMapId>IdImportWqCsv</idMapId>
<importTimeZone>
<timeZoneOffset>+00:00</timeZoneOffset>
</importTimeZone>
</general>
<properties>
<!-- Optional: decimal character. Default = '.'. By configuring a value '*' it becomes possible to import both
',' and '.' separated values in the same file -->
<string key="DECIMAL_SEPARATOR" value="*"/>
<!-- Optional: column separator character. Default = , -->
<string key="COLUMN_SEPARATOR" value=";"/>
<!-- Optional: Regular expression for date value. Default = yyyy-MM-dd -->
<string key="CSV_DATEPATTERN" value="dd-MM-yyyy"/>
<!-- Optional: select UmAquo schema version 2009 or 2011. Default = 2009 -->
<int key="SCHEMA_VERSION" value="2011"/>
<!-- Optional: allow lenient validation. Default = false -->
<bool key="LENIENT" value="true"/>
<!-- Required for WQCsv: Provide a header line describing the columns. It is important that the column separator
matches the value for the COLUMN_SEPARATOR field -->
<string key="HEADER_LINE" value=";MeetPunt.identificatie;;;Waardebepalingsmethode.code;Begindatum;Begintijd;Typering.code;;Limietsymbool;Numeriekewaarde;Hoedanigheid.code;Eenheid.code;Compartiment.code;"/>
<!-- Optional: allow import to skip the first number of lines. This can be required when the import file contains a head that does not match the above header -->
<int key="FIRST_LINE" value="1"/>
</properties>
<timeSeriesSet>
<moduleInstanceId>ImportUmAquo</moduleInstanceId>
<valueType>scalar</valueType>
<parameterId>MyPar</parameterId>
<locationSetId>MyLocSet</locationSetId>
<timeSeriesType>external historical</timeSeriesType>
<timeStep unit="nonequidistant"/>
<readWriteMode>add originals</readWriteMode>
<synchLevel>1</synchLevel>
</timeSeriesSet>
</import>
</timeSeriesImportRun>
|
...