Here is an example import module configuration file:
Code Block |
---|
<?xml version="1.0" encoding="UTF-8"?> |
...
<timeSeriesImportRun xmlns="http://www.wldelft.nl/fews" |
...
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" |
...
xsi:schemaLocation="http://www.wldelft.nl/fews [http://fews.wldelft.nl/schemas/version1.0/timeSeriesImportRun.xsd]"> |
...
<!-- This is an example import configuration file for importing WQ CSV data from an |
...
import directory --> <import> <general> <!-- Class name of WQ CSV parser is same as UmAquo CSV parser --> <parserClassName>nl.wldelft.webservice.umaquo.timeseriesparsers.UmAquoCsvTimeSeriesParser</parserClassName> |
...
<!-- Path to directory containing UmAquo libraries and schemas. If omitted then the content of the umaquo-bin |
...
can be placed in the FEWS-bin dir \--> |
...
<binDir>%REGION_HOME%/Modules/umaquo-bin</binDir> |
...
<!-- Directory from which CSV files are to be imported --> <folder>$IMPORT_FOLDER$/WQ/CSV</folder> |
...
<failedFolder>$IMPORT_FAILED_FOLDER$/WQ/CSV</failedFolder> |
...
<backupFolder>$IMPORT_BACKUP_FOLDER$/WQ/CSV</backupFolder> |
...
<idMapId>IdImportWqCsv</idMapId> <importTimeZone> <timeZoneOffset>+00:00</timeZoneOffset> |
...
</importTimeZone> </general> <properties> <!-- Optional: decimal character. Default = '.'. By configuring a value '*' it becomes possible to import both ',' and '.' separated values in the same file --> <string key="DECIMAL_SEPARATOR" value="*"/> <!-- Optional: column separator character. Default = , --> <string key="COLUMN_SEPARATOR" |
...
value=";"/> <!-- Optional: Regular expression for date value. Default = yyyy-MM-dd --> |
...
<string key="CSV_DATEPATTERN" value="dd-MM-yyyy"/> |
...
<!-- Optional: select UmAquo schema version 2009 or 2011. Default = 2009 --> |
...
<int key="SCHEMA_VERSION" value="2011"/> |
...
<!-- Optional: allow lenient validation. Default = false - |
...
-> <bool key="LENIENT" value="true"/> |
...
<!-- Required for WQCsv: Provide a header line describing the columns. It is important that the column separator matches the value for the COLUMN_SEPARATOR field - |
...
-> <string key="HEADER_LINE" value=";MeetPunt.identificatie;;;Waardebepalingsmethode.code;Begindatum;Begintijd;Typering.code;;Limietsymbool;Numeriekewaarde;Hoedanigheid.code;Eenheid.code;Compartiment.code;"/> |
...
<!-- Optional: allow import to skip the first number of lines. This can be required when the import file contains a head that does not match the above header -->
<int key="FIRST_LINE" value="1"/>
</properties>
<timeSeriesSet>
<moduleInstanceId>ImportUmAquo</moduleInstanceId>
<valueType>scalar</valueType>
<parameterId>MyPar</parameterId>
<locationSetId>MyLocSet</locationSetId>
<timeSeriesType>external historical</timeSeriesType>
<timeStep unit="nonequidistant"/>
<readWriteMode>add originals</readWriteMode>
<synchLevel>1</synchLevel>
</timeSeriesSet>
</import>
</timeSeriesImportRun>
|
Expected CSV header names
The header names that can be provided to describe the content of the WQ-CSV must be selected from the list below.
Monster.identificatie: mapped to sampling id (optional). If MeetPunt.identificatie not specified then the monster identifier is mapped to location id.
MeetPunt.identificatie: mapped to location id (required)
Typering.code: Umaquo timeseries require either Typering.code or Grootheid.code. If defined it will be used as parameter id (either Typering.code or Grootheid.code)
Grootheid.code: Umaquo timeseries require either Typering.code or Grootheid.code. If defined it will be used as parameter id (either Typering.code or Grootheid.code). Can used in combination with Parameter.code or Parameter.omschrijving
Parameter.code: mapped to parameter.id in combination with Grootheid.code. Always used in combination with Grootheid.code. : if Parameter.code not present then this column is mapped to parameter id (optional)
Parameter.codeomschrijving: mapped to parameter.id . If not present then in combination with Grootheid.code. Always used in combination with Grootheid.code is used. (optional)
Eenheid.code: mapped to timeseries unit and to qualifier 0 (required)
Hoedanigheid.code: mapped to qualifier 1 (required)
Compartiment.code: mapped to qualifier 2 (required)
Waardebepalingsmethode.code: mapped to qualifier 3 (optional)
Begindatum: mapped to timestamp together with BeginTijd (required)
Begintijd: mapped to timestamp. If not present only Begindatum is used. (optional)
Limietsymbool: mapped to OutOfDetectionRangeFlag value (optional)
Numeriekewaarde: contains numeric value. If empty then Alfanumeriekewaarde field is parsed to numeric value.
Alfanumeriekewaarde: only used if Numeriekewaarde field is empty
Kwaliteitsoordeel.code: mapped to flag value
...