| Elements | Water flows | ||
|---|---|---|---|
A | = area | P_atm | = precipitation |
atm | = atmosphere | E_atm | = evaporation |
PR | = paved roof | T_atm | = transpiration |
CP | = closed paved | R_up | = decoupled runoff |
OP | = open paved | R_ow | = runoff to open water |
UP | = unpaved | I_uz | = infiltration |
OW | = open water | P_gw | = percolation |
UZ | = unsaturated zone | D_ow | = drainage |
GW | = groundwater | S_out | = downward seepage |
MSS | = mixed sewer system | R_mss / R_swds | = runoff to sewer systems |
SWDS | = stormwater drainage system | SOF | = sewer overflow on street |
SO | = sewer overflow | Q_ow | = discharge to open water |
WWTP | = waste water treatment plant | Q_out | = discharge to outside / WWTP |
History
Originally the time step was 1 day. That way time series of more than 100-year rainfall and evaporation could be managed in EXCEL. A smaller time step could also be applied (1 hour, 15 minutes, 5 minutes). However, because of the limitations of EXCEL, a smaller time step implies much shorter time series. Transforming the water balance tool to a set of Python scripts solved this limitation. This set of Python scripts that has been combined in the Urbanwb model. This documentation describes the Urbanwb model.
...
- Atmosphere (Atm)
o Rainfall and potential evapo(transpi)ration are the main driving forces in the Urbanwb. Since the Urbanwb is a simple lumped conceptual model, other factors like temperature, relative humidity, wind and solar radiation are irrelevant. However solar radiation can be applied during preprocessing to transform daily evaporation time series into time series with smaller time steps. - Deep groundwater (Deep GW)
o Seepage from shallow groundwater (GW) to deep groundwater can be defined in the Urbanwb, either as a constant flux (downward, upward or zero) or as a dynamically computed water flow dependent on the difference between the computed groundwater level and the defined hydraulic head of the deep groundwater and on the defined vertical flow resistance. - Outside water and waste water treatment plant (Out and WWTP)
o MSS o MSS discharges its water to WWTP. The excess water in OW, i.e. water above target water level, is Water in OW can be discharged to Outside Water. Both outflows are limited by predefined discharge ratesDischarge can be defined either by a fixed discharge capacity or by a water-level-dependent Q(h) relation. When the water level in OW get Open Water level falls below the target water level, the difference is supplied by Outside Water (negative discharge)water can be supplied from Outside Water. This inlet can be limited by a user-defined inlet capacity. When a Q(h) relation is used, the target Open Water level is used only as the initial water level.
Note
A typical Dutch polder has no natural gradient for drainage, thus excessive water is normally pumped through a pumping station into a higher elevated network of larger primary canals (Figure 3) from where the water is released into sea at low tide.
Figure 3 Dutch polder system, source: Hum 300 The Arts in Society.
...
Creates an instance of PavedRoof class with given initial states and properties, iterates sol() function to compute states and fluxes of Paved Roof at each time step.
Parameters:
- intstor_pr_t0 (float) – initial interception storage on Paved Roof (at t=0) [mm]
- r_no_meas_area (float) – area of Paved Roof without measure [m^2]
- pr_meas_area (float) – area of Paved Roof with measure [m^2]
- pr_meas_inflow_area (float) – measure inflow area from Paved Roof, i.e. runoff inflow area to measure from Paved Roof (>= area of Paved Roof with measure and <= total area of Paved Roof) [m^2]
- intstorcap_pr (float) – predefined interception storage capacity on Paved Roof [mm]
- swds_frac (float) – part of urban paved area with storm water drainage system (SWDS) [-]
- discfrac_pr (float) – part of Paved Roof that is disconnected from sewer system [-]
...
Calculates measure inflow factor of Paved Roof.
Returns: Measure inflow factor of Paved Roof
...
Return type: (float)
sol(p_atm, e_pot_ow) [source]
...
Creates an instance of ClosedPaved class with given initial states and properties, iterates sol() function to compute states and fluxes of Closed Paved at each time step.
Parameters:
- intstor_pr_t0 (float) – initial interception storage on Closed Paved (at t=0) [mm]
- pr_no_meas_area (float) – area of Closed Paved without measure [m^2]
- cp_meas_area (float) – area of Closed Paved with measure [m^2]
- cp_meas_inflow_area (float) – measure inflow area from Closed Paved, i.e. runoff inflow area to measure from Closed Paved (>= area of Closed Paved with measure and <= total area of Closed Paved) [m^2]
- intstorcap_cp (float) – predefined interception storage capacity on Closed Paved [mm]
- swds_frac (float) – part of urban paved area with storm water drainage system (SWDS) [-]
- discfrac_cp (float) – part of Closed Paved that is disconnected from sewer system [-]
...
inflowfac() [source]
Calculates measure inflow factor of Closed Paved.
Returns: Measure inflow factor of Closed Paved
...
Return type: (float)
sol(p_atm, e_pot_ow) [source]
Calculates states and fluxes on Closed Paved during current time step.
Parameters:
- · p_atm (float) – rainfall during current time step [mm]
- · e_pot_ow (float) – potential Open Water evaporation during current time step [mm]
Returns: A dictionary of computed states and fluxes of Closed Paved during current time step
...
Creates an instance of OpenPaved class with given initial states and properties, iterates sol() function to compute states and fluxes of Open Paved at each time step.
Parameters:
- intstor_pr_t0 (float) – initial interception storage on Closed Paved (at t=0) [mm]
- intstor_op_t0 (float) – initial interception storage on Open Paved (at t=0) [mm]
- op_no_meas_area (float) – area of Open Paved without measure [m^2]
- op_meas_area (float) – area of Open Paved with measure [m^2]
- op_meas_inflow_area (float) – measure inflow area from Open Paved, i.e. runoff inflow area to measure from Open Paved (>= area of Open Paved with measure and <= total area of Open Paved) [m^2]
- intstorcap_op (float) – predefined interception storage capacity on Open Paved [mm]
- infilcap_op (float) – predefined infiltration capacity on Open Paved [mm/d]
- swds_frac (float) – part of urban paved area with storm water drainage system (SWDS) [-]
- discfrac_op (float) – part of Open Paved that is disconnected from sewer system [-]
...
inflowfac() [source]
Calculates measure inflow factor of Open Paved.
Returns: measure inflow factor of Open Paved
...
Return type: (float)
sol(p_atm, e_pot_ow, delta_t) [source]
Calculates states and fluxes on Open Paved during current time step.
Parameters:
- p_atm (float) – rainfall during current time step [mm]
- e_pot_ow (float) – potential Open Water evaporation during current time step [mm]
- delta_t (float) – length of time step [d]
Returns: A dictionary of computed states and fluxes of Open Paved during current time step
...
Unpaved area is a land use type that has no paved surface cover, e.g. gardens and grassland, on which the water can much more easily infiltrate than on paved surface. Vegetation (crop) type on the Unpaved area needs to be predefined. The model assumes notable distinction between paved areas (PR, CP and OP) and unpaved areas (UP). From paved areas, excess water is mainly drained through the sewer system. From unpaved areas, excess water mainly infiltrates to the unsaturated zone underneath, percolates to the groundwater and is drained via groundwater flow to the drainage system (open water). Rainfall water stored in the interception layer at the surface simultaneously evaporates to the atmosphere and infiltrates to Unsaturated Zone. Water exceeding the interception storage capacity is assumed to runoff to Open Water (OW). Figure 8 provides a schematic overview.
Figure 8 Schematic overview of Unpaved (UP) in Urbanwb
...
Creates an instance of Unpaved class with given initial states and properties, iterates sol() function to compute states and fluxes of Unpaved at each time step.
Parameters:
- fin_intstor_up_t0 – initial final remaining interception storage on Unpaved (at t=0) [mm]
- up_no_meas_area (float) – area of Unpaved without measure [m^2]
- up_meas_area (float) – area of Unpaved with measure [m^2]
- up_meas_inflow_area (float) – measure inflow area from Unpaved, i.e. runoff inflow area to measure from Unpaved (>= area of Unpaved with measure and <= total area of Unpaved) [m^2]
- intstorcap_up (float) – predefined interception storage capacity on Unpaved [mm]
- infilcap_up (float) – predefined infiltration capacity on Unpaved [mm/d]
- soiltype (int) – soil type
- croptype (int) – crop type
...
inflowfac() [source]
Calculates measure inflow factor of Unpaved.
Returns: measure inflow factor of Unpaved
...
Return type: (float)
sol(p_atm, e_pot_ow, r_pr_up, r_cp_up, r_op_up, theta_uz_prevt, pr_no_meas_area, cp_no_meas_area, op_no_meas_area, ow_no_meas_area, delta_t=0.041666666666666664) [source]
Calculates states and fluxes on Unpaved during current time step.
Parameters:
- p_atm (float) – rainfall during current time step [mm]
- e_pot_ow (float) – potential Open Water evaporation during current time step [mm]
- r_pr_up (float) – runoff from Paved Roof to Unpaved during current time step [mm]
- r_cp_up (float) – runoff from Closed Paved to Unpaved during current time step [mm]
- r_op_up (float) – runoff from Open Paved to Unpaved during current time step [mm]
- theta_uz_prevt (float) – moisture content of root zone at previous time step [mm]
- pr_no_meas_area (float) – area of Paved Roof without measure [m^2]
- cp_no_meas_area (float) – area of Closed Paved without measure [m^2]
- op_no_meas_area (float) – area of Open Paved without measure [m^2]
- ow_no_meas_area (float) – area of Open Water without measure [m^2]
- delta_t (float) – length of time step [d]
Returns: A dictionary of computed states and fluxes of Unpaved during current time step
...
Creates an instance of UnsaturatedZone class with given initial states and properties, iterates sol() function to compute states and fluxes of Unsaturated Zone at each time step.
Parameters:
- theta_uz_t0 (float) – initial (volumetric) moisture content of soil in the root zone (at t=0) [mm]
- uz_no_meas_area (float) – area of Unsaturated Zone without measure [m^2]
- uz_meas_area (float) – area of Unsaturated Zone with measure [m^2]
- soiltype (int) – soil type
- croptype (int) – crop type
sol(i_up_uz, meas_uz, e_ref, tot_meas_area, gwl_prevt, delta_t=0.041666666666666664) [source]
Calculates states and fluxes in Unsaturated Zone during current time step.
Parameters:
- i_up_uz (float) – infiltration from interception storage on Unpaved to Unsaturated Zone during current time step [mm]
- meas_uz (float) – inflow from measure to Unsaturated Zone during current time step [mm]
- e_ref (float) – reference crop evapotranspiration during current time step [mm]
- tot_meas_area (float) – total area of measure [m^2]
- gwl_prevt (float) – groundwater level at previous time step [m-SL]
- delta_t (float) – length of time step [d]
...
Returns: A dictionary of computed states and fluxes of Unsaturated Zone during current time step:
...
In the Urbanwb Model, underneath the Unsaturated Zone is the saturated zone, i.e. the Groundwater reservoir (GW). The Groundwater reservoir is modelled as an unconfined aquifer which consists of a pervious layer underlain by a (semi-)impervious layer, below which lies the deep groundwater, one of the boundary components that exchanges water with the Urbanwb model. Percolation from Unsaturated Zone and Open Paved recharges the groundwater, while downward seepage to deep groundwater and drainage to Open Water deplete the Groundwater reservoir. The inflow (percolation from Unsaturated Zone) and outflow (seepage and drainage) are driven by the head difference, so the value of these fluxes can both be positive or negative. Figure 11 shows the schematic overview of the Groundwater reservoir. The area of the Groundwater reservoir is calculated as the area of the total model minus the area of Open Water fraction that is not above the groundwater level and minus the area of Paved Roof fraction of which the basement is below groundwater. The maximum capillary rise and the storage coefficient for the current time step are determined by interpolation based on the groundwater level at the end of the previous time step.
Optionally, a bottom level can be defined for the Groundwater reservoir. The groundwater level cannot fall below this level. Because groundwater levels are expressed in metres below surface level (m-SL), a deeper groundwater level is represented by a larger value. The bottom therefore defines the maximum allowed groundwater-level value. If gw_bottom is omitted, no lower limit is applied to the Groundwater reservoir.
Figure Figure 11 Schematic overview of groundwater reservoir (GW) in Urbanwb
...
- Percolation to groundwater is the sum of percolation from Open Paved and percolation from Unsaturated Zone converted with the area ratios.
- Calculate runoff from measure to groundwater reservoir if defined possible.
- Determine the groundwater storage coefficient μ by interpolation, based on the groundwater level at the previous time step. In a database, for a given soil type, information is stored on storage coefficient for different groundwater levels (from 0 to 10 m-SL). The storage coefficient of groundwater during the current time step is interpolated from a lookup table based on the groundwater level at previous time step.
- Determine the groundwater level at the end of the current time step, based on the calculation formula mentioned above.
- Determine the total seepage to the deep groundwater (positive: downward, negative: upward) during current time step based on predefined seepage conditions. Seepage to deep groundwater can be defined either as a constant flux (0 is fixed flux) or a dynamically-computed flux (1 is level based) which depends on predefined hydraulic head of the deep groundwater and a vertical drainage resistance between the Groundwater reservoir and the deep groundwater.
- Determine the drainage from the Groundwater reservoir to the Open Water during current time step, based on a water balance. Note that here the drainage is a resulting parameter based on the other fluxes and the differences in groundwater volume (groundwater level and storage coefficient).
- Determine the groundwater level below surface level and groundwater above surface level at the end of current time step. They are dependent on groundwater level at the end of previous time step, the calculated percolation, seepage, drainage flux and storage coefficient μ during current time step.
- If gw_bottom is specified and the calculated groundwater level would fall below this bottom, first reduce drainage to Open Water and subsequently reduce downward seepage to deep groundwater until the groundwater level equals gw_bottom. The adjusted fluxes are used in the water balance.
2.6.3 Code and input arguments
...
creates an instance of Groundwater class with given initial states and properties, iterates sol() function to compute states and fluxes of groundwater at each time step.
Parameters:
- gwl_t0 (float) – initial groundwater level (at t=0) [m-SL]
- gw_ no_meas_area
- bottom (float, optional) – bottom level of the Groundwater reservoir [m-SL]. The groundwater level cannot exceed this value. If omitted, no lower limit is applied.
- gw_no_meas_area (float) – area of groundwater without measure [m^2]
- gw_meas_area area of groundwater without measure [m^2]gw_meas_area (float) – area of groundwater with measure [m^2]
- seepage_define (int) – seepage to deep groundwater defined as either constant downward flux or dynamic computed flux which is determined by head difference and resistance [0=flux; 1=level]
- w (float) – drainage resistance from groundwater to Open Water [d]
- vc (float) – vertical flow resistance from shallow groundwater to deep groundwater [d]
- head_deep_gw (float) – predefined hydraulic head of deep groundwater [m-SL]
- down_seepage_flux (float) – predefined constant downward flux from shallow groundwater to deep groundwater [mm/d]
- soiltype (int) – soil type
- croptype (int) – crop type
sol(p_uz_gw, uz_no_meas_area, p_op_gw, op_no_meas_area, tot_meas_area, meas_gw, owl_prevt, delta_t=0.041666666666666664) [source]
Calculates states and fluxes in groundwater during current time step.
Parameters:
- p_uz_gw (float) – percolation from Unsaturated Zone to groundwater during current time step [mm]
- uz_no_meas_area (float) – area of Unsaturated Zone without measure [m^2]
- p_op_gw (float) – percolation from Open Paved to groundwater during current time step [mm]
- op_no_meas_area (float) – area of Open Paved without measure [m^2]
- tot_meas_area (float) – total area of measure [m^2]
- meas_gw (float) – inflow from measure to groundwater during current time step [mm]
- owl_prevt (float) – Open Water level at previous time step [m-SL]
- delta_t (float) – length of time step [d]
Returns: A dictionary of computed states and fluxes of groundwater during current time step:
...
2.8 Open Water (required area > 0)
Open Water in the Urbanwb model refers to all controlled Open Water bodies, e.g. ditches, canals and ponds. In the Urbanwb model the open water has a fixed target level. Above this level, water will be discharged to outside water, limited by a user defined discharge capacity. In the Urbanwb model, the minimum open water level is the defined target water level. If evaporation losses result in water level below the target level, water will be let in (with unlimited capacity) from outside water to maintain the target water level. Open Water can be deemed as an abstract term reflecting system storage capacity. By assumption, all runoff from Unpaved and all sewer overflow into the street flow directly to the Open Water. Also, sewer Sewer-system outflow and groundwater drainage will also recharge the Open Water. During simulation, under successive heavy rain events, Open Water level may exceed the target level due to insufficient storage capacity and discharge capacity, indicating there is excessive water that the urban water system cannot handle. This can represent all kinds of real urban flood phenomena. In the current version of the Urbanwb model water above surface elevation level cannot flow (directly) to the other surface areas and cause flooding in these areas. Hence the maximum water level in the Open Water is not limited. The storage height above the target Open Water level is calculated to understand the storage requirements of the water system. Maximum storage height on Open Water for a certain flood event multiplied with the Open Water area reflects the required storage capacity for the total study area for that event. To sum up, Open Water component is an abstract recipient water body that indicates the required storage capacity of the system. Figure 13 shows the schematic overview of the Open Water.
Figure 13 Schematic overview of Open Water (OW) in Urbanwb
2.8.1 Assumptions
- All runoff from UP in a time step flows to OW in that same time step.
- All sewer overflow into the street from SWDS and MSS in a time step flows directly to OW in that same time step.
- A target OW level is defined as a level below the surface level. This is the lower limit of the OW level. For instance, the target OW level is set 1.5 m-SL, then the computed OW level x can only be higher than this level (x ≤ 1.5). Above this level (x < 1.5), discharge from OW to outside water starts. The outside water is not part of the model, and discharge from OW to outside is only limited by a predefined pumping capacity. Note, this pumping capacity can be applied as the discharge capacity in the Storage-Discharge-Frequency (SDF) curves, where the storages are calculation results of the Urbanwb.
2.8.2 Calculation order
Discharge from Open Water to Outside Water can be represented in two ways. A fixed discharge capacity represents, for example, a pumping station with a predefined maximum capacity. Alternatively, a Q(h) relation can be used to calculate discharge as a function of the Open Water level, for example for free drainage over a weir. These two discharge options are mutually exclusive.
When the Open Water level falls below the target level, water can be supplied from Outside Water. The maximum inlet can be limited using q_ow_in_cap. If q_ow_in_cap is omitted, the inlet capacity is unlimited. When a Q(h) relation is used, inlet from Outside Water is not allowed and ow_level defines only the initial Open Water level.
An optional Open Water bottom can be specified. This prevents the Open Water level from falling below a physically realistic floor during dry periods. During successive heavy rain events, the Open Water level may rise due to insufficient storage or discharge capacity. This indicates that the urban water system cannot discharge all incoming water.
In the current version of the Urbanwb model, water above surface level cannot flow directly to the other surface areas and cause flooding in these areas. The maximum Open Water level is therefore not limited. The storage height above the initial or reference Open Water level can be used to understand the storage requirements of the water system. The maximum storage height for a certain flood event, multiplied by the Open Water area, represents the required storage capacity for the total study area for that event. The Open Water component can therefore be regarded as an abstract recipient water body that indicates the required storage capacity of the system. Figure 13 shows the schematic overview of the Open Water.
Figure 13 Schematic overview of Open Water (OW) in Urbanwb
2.8.1 Assumptions
- All runoff from UP in a time step flows to OW in that same time step.
- All
- Determine total runoff from UP to OW for the current time step.
- Determine drainage from GW to OW for the current time step. Determine total outflow from SWDS and MSS to OW and the total
- sewer overflow into the street from SWDS and MSS to OW for the current time step.
- Determine inflow from measure (if applicable) to OW for the current time step.
- Determine discharge from OW to outside water for the current time step.
- Determine OW level at the end of the current time step.
2.8.3 Code and input arguments
...
- in a time step flows directly to OW in that same time step.
Water levels are expressed in metres below surface level (m-SL). Consequently, a larger value represents a lower water level.
When q_ow_out_cap is used, water above the target Open Water level is discharged to Outside Water, limited by the specified fixed discharge capacity.
Inlet from Outside Water is represented by a negative value of q_ow_out. The inlet is limited by q_ow_in_cap, expressed in mm/d over the total model area.
When q_ow_out_qh is used, discharge is determined from the Open Water level using linear interpolation between the supplied {h, q} points.
q_ow_out_cap
...
Bases: object
Creates an instance of OpenWater class with given initial states and properties, iterates sol() function to compute states and fluxes of Open Water at each time step.
Parameters:
...
and q_ow_out_qh are mutually exclusive. Exactly one of these discharge options must be specified.
When q_ow_out_qh is used, q_ow_in_cap must explicitly be set to 0.
When q_ow_out_qh is used, ow_level defines only the initial Open Water level and is not maintained as a target level.
If ow_bottom is specified, the Open Water level cannot fall below this bottom. Because levels are expressed below surface level, the bottom is the maximum allowed Open Water-level value.
2.8.2 Calculation order
Determine total runoff from UP to OW for the current time step.
Determine drainage from GW to OW for the current time step.
Determine total outflow from SWDS and MSS to OW and the total sewer overflow into the street from SWDS and MSS to OW for the current time step.
Determine inflow from the measure, if applicable, to OW for the current time step.
Determine direct precipitation and evaporation for the Open Water.
Determine discharge to Outside Water using either the fixed q_ow_out_cap or the water-level-dependent q_ow_out_qh relation.
When the fixed-discharge option is used and the Open Water level is below the target level, determine the required inlet from Outside Water and limit it by q_ow_in_cap.
Determine the Open Water level at the end of the current time step.
If ow_bottom is specified and the calculated level would fall below this bottom, first reduce discharge to Outside Water. If evaporation would still lower the level below the bottom, limit evaporation to the water available above ow_bottom.
Adjust the associated fluxes to the final Open Water level so that the water balance remains closed.
2.8.3 Code and input arguments
class urbanwb.openwater.OpenWater(ow_no_meas_area, ow_level, q_ow_out_cap=None, q_ow_out_qh=None, q_ow_in_cap=inf, ow_bottom=inf, **kwargs) [source]
Bases: object
Creates an instance of OpenWater class with given initial states and properties, iterates sol() function to compute states and fluxes of Open Water at each time step.
Parameters:
ow_no_meas_area (float) – area of Open Water without measure [m²]
ow_level (float) – initial Open Water level [m-SL]. When q_ow_out_cap is used, this is also the target Open Water level. When q_ow_out_qh is used, it only defines the initial level.
q_ow_out_cap (float, optional) – fixed discharge capacity from Open Water to Outside Water [mm/d over total area]. Mutually exclusive with q_ow_out_qh.
q_ow_out_qh (list, optional) – discharge relation defined by {h, q} points, where h is the Open Water level [m-SL] and q is the discharge capacity [mm/d over total area]. Mutually exclusive with q_ow_out_cap.
q_ow_in_cap (float, optional) – maximum inlet capacity from Outside Water to Open Water [mm/d over total area]. If omitted, the inlet capacity is unlimited. Must be explicitly set to 0 when q_ow_out_qh is used.
ow_bottom (float, optional) – bottom level of the Open Water store [m-SL]. The Open Water level cannot exceed this value. If omitted, no lower limit is applied.
Discharge and inlet configuration
Open Water discharge can be configured using either a fixed discharge capacity or a water-level-dependent Q(h) relation.
Fixed discharge capacity
q_ow_out_cap defines the maximum discharge from Open Water to Outside Water. When the Open Water level falls below ow_level, water can enter the Open Water from Outside Water. This inlet is represented by a negative q_ow_out and is limited by q_ow_in_cap. Both capacities are expressed in mm/d over the total model area. If q_ow_in_cap is omitted, the inlet capacity is unlimited.
Example:
q_ow_out_cap = 15
q_ow_in_cap = 2.0
Water-level-dependent discharge
q_ow_out_qh defines discharge as a function of the Open Water level using a list of {h, q} points:
- h: Open Water level in m-SL, using the same unit as owl;
- q: discharge capacity in mm/d over the total model area.
Example:
q_ow_in_cap = 0
q_ow_out_qh = [
{h = 1.0, q = 0},
{h = 0.5, q = 50},
{h = 0.0, q = 100},
]
Discharge between the supplied points is determined by linear interpolation. Below the lowest specified h, discharge is determined by linear extrapolation of the first segment. At or above the highest specified h, corresponding to the lowest water level, discharge is zero.
The following configuration rules apply:
- Specify exactly one of q_ow_out_cap and q_ow_out_qh.
- When q_ow_out_qh is used, explicitly set q_ow_in_cap = 0.
- When q_ow_out_qh is used, ow_level defines the initial Open Water level only.
Open Water and Groundwater bottoms
Optional bottom levels can be defined for the Open Water and Groundwater stores. These bottom levels prevent the modelled water levels from falling below a specified physical boundary during dry periods.
ow_bottom defines the bottom of the Open Water store in m-SL. The Open Water level cannot fall below this bottom. Because water levels are measured below surface level, a deeper level is represented by a larger value. The bottom therefore defines the maximum allowed Open Water-level value.
If the calculated Open Water level would fall below ow_bottom, discharge to Outside Water is reduced first. If evaporation alone would still lower the level below the bottom because inlet is limited, evaporation is restricted to the water available above the bottom.
gw_bottom defines the bottom of the Groundwater store in m-SL. If the calculated groundwater level would fall below gw_bottom, drainage to Open Water is reduced first. If this is insufficient, downward seepage to deep groundwater is reduced.
In both stores, the adjusted fluxes are included in the water-balance calculation so that the water balance remains closed.
Example:
q_ow_out_cap = 15
q_ow_in_cap = 2.0
ow_bottom = 1.5
gw_bottom = 3.0
Both ow_bottom and gw_bottom are optional. If omitted, no lower limit is applied to the corresponding store. Bottom levels should represent realistic physical boundaries, such as the bed level of the surface water or the base of the shallow groundwater reservoir.
...
sol(p_atm, e_pot_ow, r_up_ow, d_gw_ow, q_swds_ow, q_mss_ow, so_swds_ow, so_mss_ow, meas_ow, up_no_meas_area, gw_no_meas_area, swds_no_meas_area, mss_no_meas_area, tot_meas_area, tot_area, delta_t=0.041666666666666664) [source]
...
- Bioswale and green roof
Figure 16 shows the schematic view of how a bioswale is conceptualized. A bioswale is an infiltration installation. An bioswale can be thought as a 3-layer structure, of which the surface vegetated soil is the interception layer that provides limited storage capacity and facilitates infiltration to the growing medium. The growing medium is the top storage layer where plant transpiration and soil evaporation occur. After evapotranspiration, excessive water infiltrates into the bottom drainage layer. Below the growing medium is the gravel drainage layer encouraging water percolating into the groundwater reservoir. Here the percolation flux can be modelled either as percolation to groundwater limited by saturated permeability of soil, or as a controlled runoff to groundwater dependent on predefined drainage level and resistance to mimic the water jamming. Evaporation from the bottom drainage layer is possible when potential evapotranspiration rate exceeds the transpiration from growing medium (top storage layer), to simulate that the plant roots can uptake water from drainage layer for further transpiration. Overflow from the bottom drainage layer and surface overflow from interception layer together form the uncontrolled runoff, which will be drained to the SWDS. Similar to a bioswale, a green roof is also modelled as a 3-layer structure. However, there are two major differences: 1. A green roof is installed on the building roof, thus controlled runoff directs to the SWDS instead of to GW; 2. The calculation formula for green roofs is specifically modified to make sure no surface submergence from green roof is possible because a normally functioning green roof should have no water logging on the surface.
Figure 16 Conceptualization of a bioswale. Source left figure: [LID].
...
2.9.1 Assumptions
- A measure can be defined as 3-layer. Even though the area of each layer of measure can be defined different, it is not recommended to do so because it has not been fully tested yet.
- The measure inflow area does not necessarily come from one source. For instance, if a measure is defined in the OP area, it is possible to define the measure inflow area not only in the OP area but also in the PR and the CP area. However, these possibilities have not been fully developed and tested yet. It’s users’ responsibility to pay attention to the boundary conditions of the model.
- Not all measures can be implemented with Measure module or implemented with the Urbanwb model. The user should understand the correct way of using this Urbanwb model and should be careful with the limitations of this model.
...
Creates an instance of Measure class with given initial states and properties, iterates sol() function to compute states and fluxes of measure at each time step.
Parameters:
- tot_meas_area (float) – total area of measure [m^2]
- num_stor_lvl (int) – predefined number of storage layers [1, 2 or 3]
- runoff_to_stor_layer (int) – predefined selection at which measure layer runoff from other area is stored, inflow runoff can only take place at interception layer (1) or at bottom storage layer (3) [1 or 3]
- Active processes (#) –
- EV_evaporation (int) – predefined selection if evaporation from measure interception layer is possible (1) or not (0) [0 or 1]
- ET_transpiration (int) – predefined selection if evapotranspiration from measure is possible (1) or not (0) [0 or 1]
- IN_infiltration (int) – predefined selection if infiltration from measure is possible (1) or not (0) [0 or 1]
- SD_delay (int) – predefined selection if slow drainage from measure is possible (1) or not (0) [0 or 1]
- FD_pumping (int) – predefined selection if fast drainage from measure is possible (1) or not (0) [0 or 1]
- RTC_realtime (#) – predefined selection if real- me-control release from measure is possible (1) or not (0) [0 or 1]
- Interception layer (#) –
- storcap_int_meas (float) – predefined storage capacity of interception layer of measure [mm]
- infilcap_int_meas (float) – predefined infiltration capacity of interception layer of measure [mm/d]
- stor_int_meas_t0 (float) – initial storage in interception layer of measure (at t=0) [mm]
- Top storage layer (#) –
- top_meas_area (float) – predefined area of top storage layer of measure [m^2]
- storcap_top_meas (float) – predefined storage capacity of top storage layer of measure [mm]
- infilcap_top_meas (float) – predefined infiltration capacity of top storage layer of measure [mm/d]
- stor_top_meas_t0 (float) – initial storage in top storage layer of measure (at t=0) [mm]
- Bottom storage layer (#) –
- btm_meas_area (float) – predefined area of bottom storage layer of measure [m^2]
- storcap_btm_meas (float) – predefined storage capacity of bottom storage layer of measure [mm]
- connection_to_gw (int) – predefined percolation (connection) from measure bottom storage layer to groundwater is possible (1) or not (0) [0 or 1]
- limited_by_gwl (int) – predefined limitation of percolation from measure to groundwater if groundwater level is below measure bottom level, limited (1) or unlimited (0) [0 or 1]
- btm_level_meas (float) – predefined bottom level of measure [m-SL]
- btm_meas_transpiration (int) – predefined selection if transpiration from bottom storage layer of measure is possible (1) or not (0) [0 or 1]
- btm_discharge_type (int) – predefined discharge type from bottom storage layer of measure [0:flux or 1:level]
- runoffcap_btm_meas (float) – predefined runoff capacity from bottom storage layer of measure [mm/d]
- dischlvl_btm_meas (float) – predefined discharge level from bottom storage layer of measure [mm]
- c_btm_meas (float) – predefined hydraulic resistance for level induced discharge from bottom storage layer of measure [d]
- k_sat_uz (float) – saturation permeability of soil [mm/d]
- evaporation_factor_meas (float) – predefined evaporation factor of measure [-]
- stor_btm_meas_t0 (float) – initial storage in bottom storage layer of measure (at t=0) [mm]
- Runoff from measure flows to (#) –
- surf_runoff_meas_OW (int) – predefined definition of surface runoff from measure storage 1 (interception level) to Open Water (0 = no, 1 = yes)
- ctrl_runoff_meas_OW (int) – predefined definition of controlled runoff from measure storage 3 (bottom level) to Open Water (0 = no, 1 = yes)
- overflow_meas_OW (int) – predefined definition of overflow from measure storage 3 (bottom level) to Open Water (0 = no, 1 = yes)
- surf_runoff_meas_UZ (int) – predefined definition of surface runoff from measure storage 1 (interception level) to Unsaturated Zone (0 = no, 1 = yes)
- ctrl_runoff_meas_UZ (int) – predefined definition of controlled runoff from measure to Unsaturated Zone (0 = no, 1 = yes)
- overflow_meas_UZ (int) – predefined definition of overflow from measure to Unsaturated Zone (0 = no, 1 = yes)
- surf_runoff_meas_GW (int) – predefined definition of surface runoff from measure to groundwater (0 = no, 1 = yes)
- ctrl_runoff_meas_GW (int) – predefined definition of controlled runoff from measure to groundwater (0 = no, 1 = yes)
- overflow_meas_GW (int) – predefined definition of overflow from measure to groundwater (0 = no, 1 = yes)
- surf_runoff_meas_SWDS (int) – predefined definition of surface runoff from measure to storm water drainage system (0 = no, 1 = yes)
- ctrl_runoff_meas_SWDS (int) – predefined definition of controlled runoff from measure to storm water drainage system (0 = no, 1 = yes)
- overflow_meas_SWDS (int) – predefined definition of overflow from measure to storm water drainage system (0 = no, 1 = yes)
- surf_runoff_meas_MSS (int) – predefined definition of surface runoff from measure to mixed sewer system (0 = no, 1 = yes)
- ctrl_runoff_meas_MSS (int) – predefined definition of controlled runoff from measure to mixed sewer system (0 = no, 1 = yes)
- overflow_meas_MSS (int) – predefined definition of overflow from measure to mixed sewer system (0 = no, 1 = yes)
- surf_runoff_meas_Out (int) – predefined definition of surface runoff from measure to outside water (0 = no, 1 = yes)
- ctrl_runoff_meas_Out (int) – predefined definition of controlled runoff from measure to outside water (0 = no, 1 = yes)
- overflow_meas_Out (int) – predefined definition of overflow from measure to outside water (0 = no, 1 = yes)
sol(p_atm, e_pot_ow, r_pr_meas, r_cp_meas, r_op_meas, r_up_meas, pr_no_meas_area, cp_no_meas_area, op_no_meas_area, up_no_meas_area, gw_no_meas_area, gwl_prevt, delta_t) [source]
Calculates states and fluxes in measure during current time step.
Parameters:
- p_atm (float) – rainfall during current time step [mm]
- e_pot_ow (float) – potential Open Water evaporation during current time step [mm]
- r_pr_meas (float) – runoff from Paved Roof to measure during current time step [mm]
- r_cp_meas (float) – runoff from Closed Paved to measure during current time step [mm]
- r_op_meas (float) – runoff from Open Paved to measure during current time step [mm]
- r_up_meas (float) – runoff from Unpaved to measure during current time step [mm]
- pr_no_meas_area (float) – area of Paved Roof without measure [m^2]
- cp_no_meas_area (float) – area of closed pave without measure [m^2]
- op_no_meas_area (float) – area of Open Paved without measure [m^2]
- up_no_meas_area (float) – area of Unpaved without measure [m^2]
- gw_no_meas_area (float) – area of groundwater without measure [m^2]
- gwl_prevt (float) – groundwater level at previous time step [m-SL]
- delta_t (float) – length of time step [d]
Returns: A dictionary of computed states and fluxes of measure during current time step:
...
- DROOGERS, P. Verbetering bepaling actuele verdamping voor het strategisch waterbeheer. Definitiestudie. STOWA, 2009.
- PENMAN, Howard Latimer. Natural evaporation from Open Water, bare soil and grass. Proc. R. Soc. Lond. A, 1948, 193.1032: 120-145.
- MONTEITH, John L., et al. Evaporation and environment. In: Symp. Soc. Exp. Biol. 1965. p. 4.
- LINACRE, Edward T. Estimating US Class A pan evaporation from few climate data. Water International, 1994, 19.1: 5-14.
...