PI XML Run file example

Typically, the genaral adapter exports general adapter needs to export only one PI XML runfile run file for use by both adapters, as in the below example.:

Code Block
titleruninfo.xml
<Run xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.wldelft.nl/fews/PI" xsi:schemaLocation="http://www.wldelft.nl/fews/PI http://fews.wldelft.nl/schemas/version1.0/pi-schemas/pi_run.xsd" version="1.5">
    <timeZone>10.0</timeZone>
    <startDateTime date="2019-05-01" time="00:00:00"/>
    <endDateTime date="2020-05-01" time="00:00:00"/>
    <time0 date="2020-05-01" time="00:00:00"/>
    <lastObservationDateTime date="2020-05-01" time="00:00:00"/>
    <workDir>D:\FEWS\REGIONHOME\Modules\swmm\model</workDir>
    <inputTimeSeriesFile>D:\FEWS\REGIONHOME\Modules\swmm\input\rain.xml</inputTimeSeriesFile>
    <inputTimeSeriesFile>D:\FEWS\REGIONHOME\Modules\swmm\input\evaporation.xml</inputTimeSeriesFile>
    <inputTimeSeriesFile>D:\FEWS\REGIONHOME\Modules\swmm\input\level.xml</inputTimeSeriesFile>
    <inputTimeSeriesFile>D:\FEWS\REGIONHOME\Modules\swmm\input\flow.xml</inputTimeSeriesFile>
    <outputDiagnosticFile>D:\FEWS\REGIONHOME\Modules\swmm\piDiagnostic.xml</outputDiagnosticFile>
    <outputTimeSeriesFile>D:\FEWS\REGIONHOME\Modules\swmm\output\outputswmm_links.xml</outputTimeSeriesFile>
    <properties>
        <string key="swmm_input_file" value="$WORKDIR$/model/SWC.inp"/>
        <string key="swmm_report_file" value="$WORKDIR$/model/SWC.rpt"/>
    </properties>
</Run></startUpActivities>

...