Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • chamberOfCommerceNumber: will be used to set the value of the brocom:chamberOfCommerceNumber element.
  • qualityRegime: will be used to set the brocom:qualityRegime value. Can be either IMBRO or IMBRO/A

Optional properties that can be configured:

  • skipBroValidation: default false. Before uploading the GLD_Addition document to the BRO, the XML document will be validated using the validation API of the BRO. This is an optional feature and can make the export take a lot of time. The uploaded document will also be validated again after upload by the BRO. To disable validation, set the skipBroValidation property to true.
  • splitFiles: default false. If set to true, timeseries that have 10000 or more time steps, will be splitted in files with 9999 timesteps. The BRO Portal currently doesn't support more than 9999 time steps.
  • unitOfMeasurement: optional property to set the unit of measurement. Default value is 'm'.
  • statusQualityControl: default '"goedgekeurd" allowed values are:
    "afgekeurd", "goedgekeurd", "nogNietBeoordeeld", "onbeslist"

...

  • observationType: default "reguliereMeting" allowed values are:
    "reguliereMeting", "controleMeting"
  • statusCode:

...

  • allowed values are:
    "volledigBeoordeeld", "voorlopig"

...

  • processReference: default "NEN_EN_ISO22475v2006_C11v2010" allowed values are:
    "NEN5120v1991", "NEN_EN_ISO22475v2006_C11v2010", "NEN_ISO21413v2005", "NPR_ISO.TR23211v2009", "RWSgwmon", "STOWAgwst

...

  • "
  • measurementInstrumentType: default "druksensor" allowed values are:
    "akoestischeSensor", "akoestischHandapparaat", "analoogPeilklokje", "druksensor", "elektronischPeilklokje", "opzetStuk", "radarsensor", "stereoDruksensor"

...

  • processType: default

...

  • "Algorithm",

...

  • this appears to be the only valid option. 
  • evaluationProcedure: default "oordeelDeskundige" allowed values are:
    "brabantWater2013", "eijkelkampDataValidatiev0.0.9", "oordeelDeskundige", "PMBProtocolDatakwaliteitscontroleQC2018v2.0", "RWSAATGrondwaterv1.0", "warecoWaterDataValidatieProtocolv20200219

...

  • "
  • airPressureCompensationType: default "monitoringnetmeting" allowed values are:
    "capillair", "gecorrigeerdLokaleMeting", "KNMImeting", "monitoringnetmeting", "putlocatiemeting

...

  • "

For each exported XML file a BRO ID is required. This can either be the same as the internal locationId or (preferably) should be configured as a location attribute. In the latter case idmapping is required. The location attribute that holds the BRO ID should be mapped, using a location id function.  For example:

...