Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Background NN_Overtopping model

The Pre-adapter takes data from Delft-FEWS and creates converts this to a file called: NN_OVERTOPPING.INP as input to the NN_Overtopping model. The following parameters are used as input to the adapter:

Parameter descriptionParameter nameUnit

Angle of Wave attack

b

degr

Water depth in front of structure

h


Significant Wave Height at the toe of structure

Hm0

toe(m)

Wave period

Tm-1,0

toe(s)

Water depth at the toe of structure

ht

m

Width of toe

Bt

m

Roughness coefficient

gf


Angle of down slope

cotad


Angle of upper slope

catau


Crest Freeboard in relation to SWL

Rc

m

Berm Width

B

m

Water depth at the berm of the structure

hb

m

Berm slope

tanaB


Armour Freeboard in relation to SWL

Ac

m

Armour Width

Gcm

...

m

...

Configuration

The adapter needs to be supplied with the input and output time series files via the inputTimeSeriesFile and outputTimeSeriesFile elements so it can read and write data. The work directory needs to be specified, which must contain the NN_Overtopping model executable so it can run. A new “Runinfo.xml” file will have to be created by the general adapter for use with the new java adapter. As an additional argument the location of the Runinfo.xml file will need to be specified. The Runinfo.xml file will have to be created by the general adapter. 

The NN_Overtopping model then produces output in a file called: NN_OVERTOPPING.lis which is then converted by the adapter into an “Output.xml” file to be read into Delft-FEWS. These data use the q parameter with units of m3/s/m, along with values for q at 2.5, 5, 25, 50, 75, 95, and 97.5 %.

After When the model is run, additional processing is applied by the Post adapter, where if an input value has any of:

...

then the value is determined to be negative and marked as 0changed to 0 within the Output.xml file.. This logic was present in the previous adapter and can now be turned off, if desired, by setting the property property 'convertNegativeValues' to 'off' in the Runinfo.xml file:

Code Block
titleProperties
<properties>
    <string key="convertNegativeValues" value="off"/>
</properties>

...