Group 4: Benchmarks generated by the program itself
This section contains tests for which the reference results are generated with D-FLOW SLIDE.
4.1 Test on the level indicator
Description
To check that the level indicator is correctly inputted in D-FLOW SLIDE, the results of the two following calculations should lead to the same results:
- Benchmark 4-1a uses the same input as benchmark 1-1a, refer to paragraph 1.1 in group 1.
- Benchmark 4-1b uses the same input as benchmark 4-1a except that the Z-coordinates of the geometry are shifted by -20 m so that all points have a negative Z-coordinate.
D-FLOW SLIDE results
4.2 Test on the units
Description
In the Units tab of D-FLOW SLIDE, it is possible to specify the unit of different parameters:
- Fraction: -, %, o/oo or ppm
- Length: m, mm, cm, inch, ft or km
- Tiny length: xxxm
- Angle: deg, rad, grad, tan or cot
- Weigth: kN/m3, N/m3, lb/in3, MN/m3, lb/ft3
- Pressure: kN/m2, N/m2, Pa, kPa, MPa, kN/cm2, psi
- Permeability: m/s, m/min, m/hr, m/day
To test the correctness of the convertion , 7 benchmarks are created using the following set of units:
Benchmark name | Fraction unit | Length unit | Tiny length unit | Angle unit | Weigth unit | Pressure unit | Permeability unit |
---|---|---|---|---|---|---|---|
bm4-2a | m | xxxm | deg | kN/m3 | kN/m2 | m/s | |
bm4-2b | % | mm | xxxm | rad | N/m3 | N/m2 | m/min |
bm4-2c | o/oo | cm | xxxm | grad | lb/in3 | Pa | m/hr |
bm4-2d | ppm | inch | xxxm | tan | MN/m3 | kPa | m/day |
bm4-2e | ft | xxxm | cot | lb/ft3 | MPa | m/s | |
bm4-2f | km | xxxm | deg | kN/m3 | kN/cm2 | m/s | |
bm4-2g | m | xxxm | deg | kN/m3 | psi | m/s |