Introduction
Here you find 17 WANDA cases which help to understand the waterhammer phenomena. All cases include a movie. In order to play the movie, you must install the Techsmith ScreenCapture Codec (more information - Download).
Example 1
Description: Instantaneous valve closure at the end of a frictionless pipe
Phenomenon: Propagation of positive pressure wave
System data
Property |
Value |
---|---|
Diameter |
500 mm |
Length |
10000 m; |
Friction |
No friction |
Wave speed |
1000 m/s |
Initial velocity |
1.0 m/s |
Valve data:
- Butterfly valve
- instantaneous closure (within 1 timestep)
Example 2
Description: Instantaneous valve closure in the middle of a frictionless pipe
Phenomenon: Propagation of positive and negative pressure wave
System data
Property |
Value |
---|---|
Diameter |
500 mm |
Length |
5000 m; |
Friction |
No friction |
Wave speed |
1000 m/s |
Initial velocity |
1.0 m/s |
Valve data:
- Butterfly valve
- instantaneous closure (within 1 timestep)
Example 3
Description: Instantaneous valve closure at the end of a pipe with friction (line packing)
Phenomenon: Propagation of positive pressure wave and line packing
System data
Property |
Value |
---|---|
Diameter |
500 mm |
Length |
10000 m; |
Friction factor |
0.0222 (k = 1 mm) |
Wave speed |
1000 m/s |
Initial velocity |
1.0 m/s |
Valve data:
- Butterfly valve
- instantaneous closure (within 1 timestep)
Example 4
Description: Instantaneous valve closure at the end of a pipe with friction and surge tower as the anti-surge device
Phenomenon: Effect of surge tower on pressure waves
System data
Property |
Value |
---|---|
Diameter |
500 mm |
Length |
10000 m; |
Friction factor |
0.0222 (k = 1 mm) |
Wave speed |
1000 m/s |
Initial velocity |
1.0 m/s |
Valve data:
- Butterfly valve
- instantaneous closure (within 1 timestep)
*Surge tower:
- Area = 0.01 m2 (vertical pipe with 113 mm internal diameter)
Example 5
Description: Pump trip with small polar moment of inertia
Phenomenon: Propagation and development of negative pressure wave
System data
Property |
Value |
---|---|
Diameter |
500 mm |
Length |
10000 m; |
Friction factor |
0.0218 (k = 0.25 mm) |
Static head |
2.0 m |
Wave speed |
1000 m/s |
Initial velocity |
0.6 m/s |
Pump data:
- Duty point is 100 m3/h at 17 m head
- Polar moment of inertia 0.1 kgm2
Example 6
Description: Pump trip with large polar moment of inertia
Phenomenon: Propagation and development of negative pressure wave
System data
Property |
Value |
---|---|
Diameter |
500 mm |
Length |
10000 m; |
Friction factor |
0.0218 (k = 0.25 mm) |
Static head |
2.0 m |
Wave speed |
1000 m/s |
Initial velocity |
0.6 m/s |
Pump data:
- Duty point is 100 m3/h at 17 m head
- Polar moment of inertia 2.0 kgm2