Group 1: Benchmarks from literature (exact solution)

This section describes a number of benchmarks for which an exact analytical solution can be found in the literature.

1.1. Study Case described in "Technisch Rapport Voorland Zettingsvloeiing"

Description

The example given in "Annex A - Case Study" of the Deltares report 1200503-001-GEO-0004 "Concept Technisch Rapport Voorland Zettingsvloeiing" of G.A. van den Ham & Co is used.
In this example, both global and detailed checks are completed on the basis of a (fictitious) dike section, which with regard to geometry and soil structure is typical of the Southwest Delta.
The dike has a height of NAP+5 m, a crest width of 3 m and a slope of 1:3.
The foreshore begins to imaginary toe of the dike at an elevation of NAP and is 60 m wide. The toe of the trench is NAP-15 m and has a slope of 1:6. The dike section is 800 m long. The phreatic level is at NAP-2 m.
The soil profile is as follows:

  • from NAP+3.5 m to NAP+1 m: peat
  • from NAP+1 m to NAP-5 m: silty clay
  • from NAP-5 m to NAP-18 m: moderately to loosely compacted sand (Calais)
  • from NAP-18 m to NAP-30 m: densely compacted sand
Benchmarks results

The details of the calculation can be found in annex A of the report. The main results are given in the table below. The global check fails but the detailed check passes.

D-Flow Slide results
Results of benchmark 1-1 for the Global Check

 

Unit

Benchmark

D-FLOW SLIDE

Relative error

Marge

[m]

35

35

0.00%

X coordinate of the observation profile (Xsign)

[m]

-35

-35

0.00%

X coordinate of the liquefaction point (XZV)

[m]

30

30

0.00%

Question 1 : Would flow slide lead to damage on levee?

 

Yes

Yes

OK

Question 2: Criterion on slope protection met (<1:2,5)? 

- 

Question 3: Artificially underwater installed and non-compacted sandy foreland?

 

No

No

OK

Question 4: Flow slide possible based on geometry only?

 

Yes

Yes

OK

Question 5: Is liquefaction possible? -Yes 

Question 6: Are there any sensitive to liquefaction layers present?

 

Yes

Yes

OK

Question 7: Is unstable breaching possible? -Yes 

Result of the Global check

 

Failed

Failed

OK

Results of benchmark 1-1 for the Detailed Check

 

Unit

Benchmark

D-FLOW SLIDE

Relative error

Fictive channel depth (Hr)

[m]

21.571

21.571

0.00 %

Fictive slope (cotan αr)

[-]

10.500

10.500

0.00 %

Probability of liquefaction

[-]

2.93 × 1E-03

2.93 × 1E-03

0.00 %

Representative probability of failure

[-]

3.52 × 1E-03

3.52 × 1E-03

0.00 %

β

[-]

3.749

3.749

0.00 %

P(L > Lallowable)

[-]

8.87 × 1E-05

8.86 × 1E-05

0.08 %

Probability of failure

[-]

3.12 × 1E-07

3.12 × 1E-07

0.00 %

Allowable probability of failure

[-]

2.50 × 1E-06

2.50 × 1E-06

0.00 %

Result of Detailed Check

 

Succeeded

Succeeded

(plus)

 

1.2. Critical slope for Global breaching check

Description

The average slope given in Table A.4.2a from CUR113b  profile without flat berms:is modeled in D-Flow Slide for both type of sand (not too fine and fairly coarse). 

Different cases are considered:

CaseType of sandNumber of flat bermDescriptionExpected result for breaching 
Anot too fine sand0The inputted soil profile is the same as in Table A.4.2a from CUR113b   Fail
  0The inputted profile is the same as in Table A.4.2a from CUR113b  except that the slope from depth 0 to 5 m is steeper (1:1.9)  Fail
  0The profile is the same as in Table A.4.2a from CUR113b  except that the slope from depth 0 to 5 m is softer (1:1.2.1) Pass
     
     
     
     
     
     
     
     
     
     
     
     
Benchmarks results

The values of the slope is given in xxx.

D-Flow Slide results
Results of benchmark 1-1 for the Global Check

 

Unit

Benchmark

D-FLOW SLIDE

Relative error

Marge

[m]

35

35

0.00%

X coordinate of the observation profile (Xsign)

[m]

-35

-35

0.00%

X coordinate of the liquefaction point (XZV)

[m]

30

30

0.00%

Question 1 : Would flow slide lead to damage on levee?

 

Yes

Yes

OK

Question 2: Criterion on slope protection met (<1:2,5)? 

- 

Question 3: Artificially underwater installed and non-compacted sandy foreland?

 

No

No

OK

Question 4: Flow slide possible based on geometry only?

 

Yes

Yes

OK

Question 5: Is liquefaction possible? -Yes 

Question 6: Are there any sensitive to liquefaction layers present?

 

Yes

Yes

OK

Question 7: Is unstable breaching possible? -Yes 

Result of the Global check

 

Failed

Failed

OK

Results of benchmark 1-1 for the Detailed Check

 