Read this article when you have a SOBEK 2 model and you want to convert it to SOBEK 3. If you want to import a DUFLOW model, see reference Jeuken (2014).

Preface

SOBEK 3 is refaced against SOBEK 2 in terms of modeling concept and features. This means that some features in SOBEK 2 are no longer supported and some objects are modelled in a different way.

The following table gives an overview about differences in the modelling concepts between SOBEK 2 and SOBEK 3:

SOBEK 2SOBEK 3
Hydraulic structures in channel flow module and rainfall runoff moduleHydraulic structures in D-Flow 1D module only
Control of structures in channel flow module and RTC moduleAll control of structures in D-Real-Time Control module (D-RTC)
Rainfall-runoff module contains open water nodeD-Rainfall Runoff (D-RR) has no open water node, it contains only rainfall-runoff processes.
Rational method in channel flow module (lateral station node) and rainfall-runoff moduleNo rational method in D-Flow 1D. The rational method is only available in D-Rainfall Runoff
Storage and lateral node available in channel flow moduleD-Flow 1D does not contain a storage and lateral node (planned feature)

Approach

Import the SOBEK 2 model into SOBEK 3 and choose features

Procedure:

1D flow

Clean up the SOBEK 2 model

First clean up the SOBEK 2 model with the Cleanup Utility:

Import to SOBEK 3

Now create a SOBEK 2 model that can be imported in such a way that there is no difference between the SOBEK 2  model and the SOBEK 3 model with regards to the contents.

This is an iterative process:

To import the model, use the SOBEK 3 import tool:

SOBEK 3 import window. Choose "SOBEK Model (Flow 1D, RTC, RR, WAQ)". This window is accessible via File --> Import

Select case after opening CASELIST.CMT

Dependent from the choices you make, you receive an integrated model with the following sub-models:

The following list gives examples for modifications that might be necessary:

The following warning messages do not require any modifications in the model, but can explain different model results:

Compare simulation results and modify model data

Change the numerical parameters Iadvec1D from 4 to 1 and Limtyphu1D from 100 to 0 according to SOBEK 3 user manual, section 5.10.2.10 (Parameter set for comparison with SOBEK 2, Deltares Systems, 2013).

Run a simulation with your modified SOBEK 2 model with the channel flow module only.

Validate your SOBEK 3 model with the validation feature.

Validate model tool. This tool is available after right-mouse click on a model. Choose "Validate...".

Check the warning messages and make the necessary changes. Possible necessary changes are:

Run a simulation with the corresponding SOBEK 3 model. Compare the results. Results may differ due to changes in the model approach. The following table gives an overview about the differences in model approach between SOBEK 2 and SOBEK 3:

issueSOBEK 2SOBEK 3Modification in SOBEK 2
Controller operations on pumps, handling of initial valueWhen the initial waterlevel is in the range of the deadband between switch on and switch off level, in SOBEK2 the pump is onWhen the initial waterlevel is in the range of the deadband between switch on and switch off level, in SOBEK2 the pump is on.
  1. Change the controller time series in such a way that pump shows the same behaviour in both models.
  2. Check the initial water level
    

Modify the SOBEK 2 model in such a way that the corresponding SOBEK 3 model produces the same results. This is not possible in all cases (Meijer, 2015).

Finalization 1D-Flow

Preface

Within the finalization phase, features that could not be imported from the original SOBEK 2 model must be added:

If the model has a long history, modify your model according to good modeling practice:

Consider to use the scripting feature of SOBEK 3. Example scripts are delivered with SOBEK 3.

Lateral stations in 1D-Flow with rational method

If your SOBEK 2 1D-Flow model contains lateral stations that get inflow from rainfall-runoff features like

these features must be added manually within a rainfall-runoff (D-RR) model.

References

Deltares Systems (2013): 1D/2D modelling suite for integral water solutions / SOBEK Suite / D-Flow 1D and D-Real Time Control in Delta Shell / User manual. Version: 3.0.1.29328, 30 July 2013 Deltares: Delft, The Netherlands.

Meijer, D. (2015): Results acceptance test FLOW 1D and RTC SOBEK 3. Deltares draft report 1205718-000-DSC-0124-v1.

Velner, R.; Meijers, E.; Ketelaar, H.; Heeringen, J.-J.; Stout, J.; van Putten, H. (2013): Pilot: testen van SOBEK3.1 o.b.v. DeltaShell bij Waterschap Rivierenland. Eindrapport. Waterschap Rivierenland. file: PilotSobekDeltaShellWSRL_Groeidocument_v09_final.doc

Jeuken, M. (2014): Tips bij het converteren van DUFLOW modelschematisaties naar SOBEK 3. Deltares-memo,
You may also want to use visual panels to communicate related information, tips or things users need to be aware of.

Related articles

Related articles appear here based on the labels you select. Click to edit the macro and add or change labels.