- Check the FEWS export activities
- Check that the export activities section of the general adapter is configured for the correct time series and grid data sets
- Examine the ImportIdMap ExportIdMap for parameter and location mapping.
- Run the model outside of Delft-FEWS in a separate directory
- Compare the input files generated by Delft-FEWS to the input files used previously
- Are the formats consistent? Are the headers the same? Is the data the same?
- If not, you may be using a different data format. Check if this data format is compatible with FEWS. If the format is correct, check the log files from the pre-adapter for more information.
- Check the external module
- Run the model outside of Delft-FEWS, but use the input files generated by the pre-adapter
- If the model doesn't run properly, examine the model log files for more information.
- If the model does run properly and output is generated move to the next step.
- Run the model outside of Delft-FEWS, but use the input files generated by the pre-adapter
- Check the FEWS import activities
- Examine the output files from the model in native format
- Do you see what you expect to see? If not, re-examine the model input and log files.
- Examine the files generated by the post-adapter (if any)
- Check that the data format is compatible with FEWS, If the format is correct, check the log files from the post-adapter for more information.
- Examine the ExportIdMap ImportIdMap for parameter and location mapping.
- Check that the import activities section of the general adapter is configured for the correct time series and grid data sets
- Use the Workflow Navigator and Database Viewer to determine if data is imported and present in the localDataStore
- Examine the output files from the model in native format
...