Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Group 4: Benchmarks generated by the program itself

This section contains should contain tests for which the reference results are generated with D-FLOW SLIDE.

4.1 Test on the level indicator

Description

To check that the level indicator is correctly inputted in D-FLOW SLIDE, the results of the two following calculations should lead to the same results:

  • Benchmark 4-1a uses the same input as benchmark 1-1a, refer to paragraph 1.1 in group 1.
  • Benchmark 4-1b uses the same input as benchmark 4-1a except that the Z-coordinates of the geometry are shifted by -20 m so that all points have a negative Z-coordinate.
D-FLOW SLIDE results

4.2 Test on the units

Description

In the Units tab of D-FLOW SLIDE, it is possible to specify the unit of different parameters:

  • Fraction: -, %, o/oo or ppm
  • Length: m, mm, cm, inch, ft or km
  • Tiny length: xxxm
  • Angle: deg, rad, grad, tan or cot
  • Weigth: kN/m3, N/m3, lb/in3, MN/m3, lb/ft3
  • Pressure: kN/m2, N/m2, Pa, kPa, MPa, kN/cm2, psi
  • Permeability: m/s, m/min, m/hr, m/day

To test the correctness of the convertion , 7 benchmarks are created using the following set of units:

...

Benchmark name

...

Fraction unit

...

Length unit

...

Tiny length unit

...

Angle unit

...

Weigth unit

...

Pressure unit

...

Permeability unit

...

bm4-2a

...

m

...

xxxm

...

deg

...

kN/m3

...

kN/m2

...

m/s

...

bm4-2b

...

%

...

mm

...

xxxm

...

rad

...

N/m3

...

N/m2

...

m/min

...

bm4-2c

...

o/oo

...

cm

...

xxxm

...

grad

...

lb/in3

...

Pa

...

m/hr

...

bm4-2d

...

ppm

...

inch

...

xxxm

...

tan

...

MN/m3

...

kPa

...

m/day

...

bm4-2e

...

ft

...

xxxm

...

cot

...

lb/ft3

...

MPa

...

m/s

...

bm4-2f

...

km

...

xxxm

...

deg

...

kN/m3

...

kN/cm2

...

m/s

Currently, no benchmarks are related to this group.

 

...

bm4-2g

...

m

...

xxxm

...

deg

...

kN/m3

...

psi

...