D-Flow Slide needs extra input parameters compared to the Study Case:
- Ψ5m = -0.03 for sand layers and Ψ5m = -0.06 for other layers (used in Global step 1)
- Ψ5m = -0.03 (used in Global step 5 and Detailed checks)
- D50 = 180 μm and D15 = 130 μm for Calais sand
- D50 = 160 μm and D15 = 110 μm for Compacted sand
- Cohesive layers factor = 0.2
- Migration velocity = 0.0001 mm/year
...
| Unit | Benchmark | D-FLOW SLIDE | Relative error |
---|---|---|---|---|
Marge | [m] | 35 | 35 | 0.00% |
X coordinate of the observation profile (Xsign) | [m] | -35 | -35 | 0.00% |
X coordinate of the liquefaction point (XZV) | [m] | 30 | 30 | 0.00% |
Question 1 1a : Would flow slide lead to damage on levee? |
| Yes | Yes | OK |
Question 21b: Criterion on slope protection met (<1:2,5)? | - | - | ||
Question 31c: Artificially underwater installed and non-compacted sandy foreland? |
| No | No | OK |
Question 41d: Flow slide possible based on geometry onlyon criterion "steepest slope over 5 m"? |
| Yes | Yes | OK |
Question 51e: Is liquefaction possibleFlow slide possible based on average geometry only? | - | Yes | ||
Question 6: Are there any sensitive to liquefaction layers present? |
| Yes | Yes | OK |
Question 7: Is breaching possible? | - | Yes | ||
Result of the Global check |
| Failed | Failed | OK |
...