If the option <initialStartTimeCardinalTimeStep> is used then the start time will not change when the system time changes. The same applies for the end time and the option <initialEndTimeCardinalTimeStep>.

...

A configuration example of a node for which a forecast length, an <initialForecastLengthCardinalTimeStep> and a <cardinalTimeStepForecastLength> is configured is shown below.

Code Block
languagexml
				<node id="B10_Main_RTC" name="Run model">
					<workflowId>Big10_RTCTools_RT</workflowId>
					<forecastLength unit="hour" multiplier="24"/>
					<cardinalTimeStepForecastLength unit="hour"/>
					<initialForecastLengthCardinalTimeStep idunit="hour" multiplier="HE66"/>
					<displayGroupId>Main_RT-RTC</displayGroupId>
					<timeSeriesButtonsPanelId>RT_buttons_Main</timeSeriesButtonsPanelId>
					<viewPermission>execute</viewPermission>
					<visibleModifierGroup>RT</visibleModifierGroup>
					<graceTime unit="hour" multiplier="1"/>
					<localRun>true</localRun>
					<saveLocalRunEnabled>true</saveLocalRunEnabled>
					<showRunApprovedForecastButton>true</showRunApprovedForecastButton>
				</node>

 

Below a screenshot of this node after it is selected for the first time is shown.

...