...
The following documents play a role in the generation of alerts.
- ModuleConfigFielsModuleConfigFiles\<secondaryValidation>.xml
Contains the secondary validation rules that will generate logEventCodes that become visible in the logging when rules are exceeded. The log messages generated are defined in this file as well by means of <logEventCode>. It makes sense to choose sensible logEventCodes, for example all log messages used together with the Alarmmodule might start with "Alert.", see also the next section on this. File name is free to choose, secondaryValidation refers to the xsd that is used. - RegionConfigFiles\ all three threshold configuration files. See also the wiki page on this: 09 Thresholds
- RegionConfigFiles\Thresholds.xml
Defines the level for each threshold with <levelThreshold>. These thresholds can be used to change colors and the use of Flags in the Displays - RegionConfigFiles\TresholdValueSets.xml
Links timeSeriesSets to <thresholdValueSets> - RegionConfigFiles\TresholdWarningLevels.xml
Can be used to define the overlays and colors used when <thresholdWarningLevels> are exceeded, both up and down..
- RegionConfigFiles\Thresholds.xml
- DisplayConfigFiles\<scadaDisplay>.xml
Defines the scada display in which alerts can be used by means of <shapeComponentBehaviourDefinition>. File name is free to choose, scadaDisplay refers to the xsd that is used.
...