  • ModuleConfigFiles\<secondaryValidation>.xml
    Contains the secondary validation rules that will generate logEventCodes that become visible in the logging when rules are exceeded. The log messages generated are defined in this file as well by means of <logEventCode>. It makes sense to choose sensible logEventCodes, for example all log messages used together with the Alarmmodule might start with "Alert.", see also the next section on this. File name is free to choose, secondaryValidation refers to the xsd that is used.
  • RegionConfigFiles\ all three threshold configuration files. See also the wiki page on this: 09 Thresholds
    • RegionConfigFiles\Thresholds.xml
      Defines the level for each threshold with <levelThreshold>. These thresholds can be used to change colors and the use of Flags in the Displays
    • RegionConfigFiles\TresholdValueSetsThresholdValueSets.xml
      Links timeSeriesSets to <thresholdValueSets>
    • RegionConfigFiles\TresholdWarningLevelsThresholdWarningLevels.xml
      Can be used to define the overlays and colors used when <thresholdWarningLevels> are exceeded, both up and down..
  • DisplayConfigFiles\<scadaDisplay>.xml
    Defines the scada display in which alerts can be used by means of <shapeComponentBehaviourDefinition>. File name is free to choose, scadaDisplay refers to the xsd that is used.

...

  • Status is suspended, or <taskStatus>S</taskStatus>
  • Tag is Alarmmodule.alarm, or <taskTag>Alarmmodule.alarm</taskTag>
    (Note: the screenshot of the Admin Interface doesn't match the example, but shows the tag ALARM_MODULE)
  • Interval is One-off task, or <taskSelection><singleTask><time0>2011-08-23T09:05:00.000Z</time0></singleTask></taskSelection>
  • Configure webserviceURL of the Alarmmodule, or <webserviceURL>http<webserviceURL>http://localhost:8989/AlarmModuleManager/webservices/alarmService</webserviceURLwebserviceURL>>
    This is an example based on the IWP system. The webservice of the <alarmModuleAlert> is the URL of the webservice of the alarm module that has been set-up according to the specifications of Imtech.
  • Alert message is configured as part of the task properties of the scheduled MC_SystemAlerter task, this can be either a
    • Fixed alert message, or <alarmDiagLine code="IWP_0_TEST" description="Test Alert from FEWS" source="MC01" level="1"/>, or a
    • Template alert message, or <alarmDiagTemplateLine code="%EVENT_CODE%" description="%LOG%" source="%MC_ID%" level="1"/>, in which

      • %LOG% will be replaced by the message part of log entry that triggered the Event Action
      • %EVENT_CODE% will be replaced by the event code of the log entry that triggered the Event Action
      • %MC_ID% will be replaced by the MasterController ID creating the log entry that triggered the Event Action

...