  • Id: Id of the workflow. This Id must be unique. Normally a string is used that gives some understanding of the role of the module (e.g. ImportExternal).
  • name: Optional name for the module. Used for reference purposes only.
  • visible: Boolean toggle to indicate if workflow is visible for selection in the manual forecast display. Default is true.
  • Forecast: Boolean flag to indicated if workflow is identified as a forecast. This should be the case for workflows with simulated time series as a results. Only Forecast workflows can be approved and made current. Import workflows of external data are not forecasts. Default is true.
  • allowApprove. Boolean flag to indicate if workflow may be approved a-priori through manual forecast display (stand-alone only). Default is true.
  • allowSelection: Boolean flag to indicate if workflow can be executed for specific selected locations. Default is false
  • autoApprove. Boolean flag to indicate workflow should automatically be approved a-priori (stand-alone only). Default is false.
  • autoSetSystemTime. Boolean flag to indicate workflow should automatically adjust the system time. When the workflow is completed and is fully or partly successful, the system time wil be set to the start time of the period written by this workflow.
    If the start time is not a valid time in accordance with the cardinal timestep, the next valid time wil be used.
    Default flag value is false. Applicable only on stand-alone.
  • maxEnsembleParts: Positive integer. Determines in how many parts (i.e. forecasting shell instances available) at most the workflow can be split up to run in parallel for ensembles. Ensembles can/will only be split up if this element is specified and the number specified is larger than 1.
  • timeOut: optional timeout that a workflow is allowed to run before the Forecasting Shell terminates it. This setting is independent of the master controller chaser. Therefore it makes only sense to specify a time out smaller than the master-controller chaser grace time.
  • showWarningInLogCompletion: Boolean to report whether warning messages were logged during the execution of the workflow, default false.
  • waterCoachDelay: Prevents simulated forecasts becoming available too early in water coach mode. The forecasts are finished in real life at time zero plus delay. The delay includes the run time and the time0 shift. When a forecast is scheduled at 7:00 am with a time0 of 0:00 am and the runs takes approximately an hour you should specify an delay of 8 hours. For external forecasts the delay is configured in the moduleInstanceDescriptors.xml
  • runExpirytime: Used for runs of simulated timeseries to override expiry time from global properties DEFAULT_EXPIRY_DAYS. When timeseriesets expirytime is also configured, the minimum of runExpiryTime and the timeSeriesSets expirytime is used. Obsolete for import data since 2017.01.

...