To make sure the amount of output produced by SOBEK is no more than needed, it is important to uncheck all unnecessary output creation. If only water depth is needed in 2D then only have this option checked.

 


Settings inside the SOBEK module directory

...

variable

required

default value

meaning

example

version

yes 


Version of Batch Data Structure

2

projectDir

yes

 


SOBEK project directory

BosRegge.lit

caseName

yes

 


Case name as in SOBEK project

Basismodel voor voorspelinstrument 101105, WL 20060404

showTablesFlipped

no

FALSE

Option to show all the input and output tables in the user interface flipped (true=horizontal, false = vertical)

TRUE

resultsHisFile

no 


Output filename

Output\Output.his

dataPath

no 


Path where all kind of info files are stored

Output

resultsSaved

no

FALSE

If the results have been saved and are availalbe

TRUE

parInfoFile

no

 


Filename of file with parameter information

Output\Output_par.csv

storeWorkDir

no

FALSE

Option to save the complete working directory

FALSE

workDirStored

no

FALSE

Option to determine if working directory has been saved

FALSE

storeOutputInOneFile

no

FALSE

Option to save all the output in one output file, which is required for FEWS

TRUE

storeFEWSState

no

FALSE

Option to save state information, which is required for FEWS

TRUE

fewsDiagnosticsFile

no 


Filename of FEWS diagnostics file

Logs\Diagnostics.xml

clearWorkingDirectories

no

TRUE

Option to clear working directory after running the simulation

FALSE

skipTimeSteps

no

0

Number of timesteps to be skipped when converted FEWS ASCII Meteo file to Bui file.

0

useXMLBinFileType

no

FALSE

Option to write Delft-FEWS PI files with binary data section. Improves performence very much, but bad to check the contents of the PI files. Only use this if everything is going right.....

TRUE

useParsenUpdateMode

yes

FALSE

Option to let the PARSEN of the Flow modules only update the time series in the NEFIS files. Might improve performence very much, but does not pick up any other updated data from the MDB Files

FALSE

parsenMinimumTimeSeriesLength

yes

1000

If useParsenUpdateMode is TRUE, it is required to define the number of timesteps to generate in the time series tables. Value must be higher than zero.

1000

parsenSourceFiles

yes 


If useParsenUpdateMode is TRUE, the source files which should be updated by the PARSEN must be defined here.

Defaults\sobek.*

...

The adapter software is installed as part of the SOBEK installation in the Programs folder. However, due to various features extensions, a later version of the SbkBatch.exe (and the corresponding sobekAdvancedBatchcorresponding sobekAdvancedBatch.xsd) can be needed. Therefore the latest version of both can be found here:

...