Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The following are the required properties that have to be configured:

  • projectId: a project Id (projectnummer) provided by BRO which can be found by logging in on bronhouderportaal-bro.nl
  • chamberOfCommerceNumber: will be used to set the value of the brocom:chamberOfCommerceNumber element.
  • qualityRegime: will be used to set the brocom:qualityRegime value. Can be either IMBRO or IMBRO/A

...

  • unitOfMeasurement: optional property to set the unit of measurement. Default value is 'm'.
  • skipBroValidation: skip the initial validation step (document processing always includes the second validation step). 
  • splitFiles: default true. If set to true, timeseries that have 10000 or more time steps, will be split in files with 9999 timesteps. The BRO Portal currently doesn't support more than 9999 time steps.
  • statusQualityControl: default '"goedgekeurd" allowed values are:
    "afgekeurd", "goedgekeurd", "nogNietBeoordeeld", "onbeslist", "onbekend"
  • observationType: default "reguliereMeting" allowed values are:
    "reguliereMeting", "controleMeting"
  • statusCode: default is none  allowed values are:
    "volledigBeoordeeld", "voorlopig", "onbekend"
  • processReference: default "NEN_EN_ISO22475v2006_C11v2010" allowed values are:
    "NEN5120v1991", "NEN_EN_ISO22475v2006_C11v2010", "NEN_ISO21413v2005", "NPR_ISO.TR23211v2009", "RWSgwmon", "STOWAgwst", "vitensMeetprotocolGrondwater", "waternetMeetprocedure", "onbekend"
  • measurementInstrumentType: default "druksensor" allowed values are:
    "akoestischeSensor", "akoestischHandapparaat", "analoogPeilklokje", "druksensor", "elektronischPeilklokje", "opzetStuk", "radarsensor", "stereoDruksensor", "onbekend", "onbekendPeilklokje"
  • processType: default "" allowed values are:
    "Algorithm", "Manual Method", "Sensor", "Simulation", "Unknown"
  • evaluationProcedure: default "oordeelDeskundige" allowed values are:
    "brabantWater2013", "eijkelkampDataValidatiev0.0.9", "oordeelDeskundige", "PMBProtocolDatakwaliteitscontroleQC2018v2.0", "RWSAATGrondwaterv1.0", "validatieprocedureEvidesWaterbedrijf", "vitensBeoordelingsprotocolGrondwater", "waternetBeoordelingsprocedure", "warecoWaterDataValidatieProtocolv20200219", "onbekend"
  • airPressureCompensationType: default is none, allowed values are:
    "capillair", "gecorrigeerdLokaleMeting", "KNMImeting", "monitoringnetmeting", "putlocatiemeting", "onbekend"

...