idpump_control
The PUMP component does not listen to the Control-system

Cloak
idpump_control

In Wanda 3.60, the pump only listens to the control system when the property drive type is set to "Running" or "MotorFreq". This will be fixed in Wanda 3.70 where the pump can be used with a control system regardless of the drive-type setting (except for the "Level On/Off"-setting, which is a control system in itself).

Toggle Cloak
idpump_control2
The PUMP with drivetype = motorfreq cannot use a logical control input.

Cloak
idpump_control2

The PUMP component can only recieve a logical control input when the drive-type property is set to trip. With drive-type=motorfreq the component expects a numerical input signal specifying the relative frequency. This means that the input can vary between 0 and 1.