Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Group

File name

Input file
D-Flow Slide (*.fsx)

Input file
SLIQ2D 1.1.3.1 (*.slq)

Input file
SLIQ2D-Dos (*.sli)

Title

Global (VTV)

Simple (CUR-113)

Detailed (TR)

Advanced (SLIQ2D)

1

bm1-1

 

 

 

Study Case described in "Technisch Rapport Voorland Zettingsvloeiing"

Insufficient / Insufficient => (tick)

 

Sufficient / Sufficient => (tick)

 

2

bm2-1

 

 

 

Spui dike - hmp 63.9 (location Nieuw Beijerland)

Insufficient / Insufficient => (tick)

 

Insufficient / Insufficient => (tick)

 

 

bm2-2

 

 

 

Spui dike - hmp 65.0 (between locations Oud Beijerland and Nieuw Beijerland)

Sufficient / Sufficient => (tick)

 

Sufficient / Sufficient => (tick)

 

 

bm2-3

 

 

 

Spui dike - hmp 67.8 (locationoud location Oud Beijerland)

Insufficient / Insufficient => (tick)

 

Insufficient / Sufficient => (error)

 

3

bm3-1

 

 

 

Global check with traject: step 1 = no, step 3 = yes

 

 

 

 

 

bm3-2

 

 

 

Global check with traject: step 1 = no, step 3 = no

 

 

 

 

 

bm3-3

 

 

 

Global check with traject:

 

 

 

 

4

bm4-1

 

 

 

Test on the level indicator

 

 

 

 

5

bm5-1a

 

 

 

Comparison with SLIQ2D - Case LGZM1

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-1b

 

 

 

Comparison with SLIQ2D - Case LGZM2

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-1c

 

 

 

Comparison with SLIQ2D - Case LGZM3

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-1d

 

 

 

Comparison with SLIQ2D - Case LGZM4

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-1e

 

 

 

Comparison with SLIQ2D - Case SIMPLETA

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-1f

 

 

 

Comparison with SLIQ2D - Case LG1D5N5H

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-1g

 

 

 

Comparison with SLIQ2D - Case HBPZBUI3

 

 

 

Insufficient / Insufficient => (tick)

 

bm5-2

 

 

 

Comparison with DZettingsVloeiing - Study Case described in "Technisch Rapport Voorland Zettingsvloeiing"

 

 

Sufficient / Sufficient => (tick)

 

(warning) According to hand-calculation, the Advanced check passes but according to D-Flow Slide it fails.

Group 1: Benchmarks from literature (exact solution)

...

  • km 63.9 (Nieuw Beijerland)
  • km 65.0 (between Oud Beijerland and Nieuw Beijerland)
  • km 67.8 (oud Oud Beijerland)

As the details of the calculation performed by hand are not available, those benchmarks are set in group 2.

...