Setting up a (temporary) display to view the imported data

Test the import

...

Delft-Fews only shows data is you specifically tel it to show data. The file DisplayGroups.xml (located in the SystemConfigFiles directory) defines pre-defined graphs. In the example below five graphs have been defined to view the newly imported data:

No Format

<?xml version="1.0" encoding="UTF-8"?>
<displayGroups version="1.0" 
xmlns="http://www.wldelft.nl/fews" 
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
xsi:schemaLocation="http://www.wldelft.nl/fews 
http://fews.wldelft.nl/schemas/version1.0/displayGroups.xsd">
	<displayGroup name="Test">
		<display name="Gauge One">
			<relativeViewPeriod unit="hour" start="-12" end="36"/>
			<subplot>
				<timeSeriesSet>
					<moduleInstanceId>Import</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>H.obs</parameterId>
					<locationId>one</locationId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="hour" multiplier="1"/>
					<relativeViewPeriod unit="hour" end="48" start="-48"/>
					<readWriteMode>add originals</readWriteMode>
				</timeSeriesSet>
			</subplot>
		</display>
		<display name="Gauge Two">
			<relativeViewPeriod unit="hour" start="-12" end="36"/>
			<subplot>
				<timeSeriesSet>
					<moduleInstanceId>Import</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>H.obs</parameterId>
					<locationId>two</locationId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="hour" multiplier="1"/>
					<relativeViewPeriod unit="hour" end="48" start="-48"/>
					<readWriteMode>add originals</readWriteMode>
				</timeSeriesSet>
			</subplot>
		</display>
		<display name="Gauge Three">
			<relativeViewPeriod unit="hour" start="-12" end="36"/>
			<subplot>
				<timeSeriesSet>
					<moduleInstanceId>Import</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>H.obs</parameterId>
					<locationId>three</locationId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="hour" multiplier="1"/>
					<relativeViewPeriod unit="hour" end="48" start="-48"/>
					<readWriteMode>add originals</readWriteMode>
				</timeSeriesSet>
			</subplot>
		</display>
		<display name="Gauge Four">
			<relativeViewPeriod unit="hour" start="-12" end="36"/>
			<subplot>
				<timeSeriesSet>
					<moduleInstanceId>Import</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>H.obs</parameterId>
					<locationId>four</locationId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="hour" multiplier="1"/>
					<relativeViewPeriod unit="hour" end="48" start="-48"/>
					<readWriteMode>add originals</readWriteMode>
				</timeSeriesSet>
			</subplot>
		</display>
		<display name="All together">
			<relativeViewPeriod unit="hour" start="-12" end="36"/>
			<subplot>
				<timeSeriesSet>
					<moduleInstanceId>Import</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>H.obs</parameterId>
					<locationSetId>LevelGauges</locationSetId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="hour" multiplier="1"/>
					<relativeViewPeriod unit="hour" end="48" start="-48"/>
					<readWriteMode>add originals</readWriteMode>
				</timeSeriesSet>
			</subplot>
		</display>
	</displayGroup>
</displayGroups>

Test the import

To test the import run the ImportExternal Workflow. Check to log panel for error messages. If you want to view the data please make sure to first set the system time to a time/data you have data for. In this example August 23 2006.

Add to the appropriate filters(s)

To be able to use the main map display and the filter to access the data you should set up en entry in the Filters.xml file in the RegionConfigFiles directory. See the example below:

No Format