A complete import module configuration consists of an ID Mapping file and a Import Module Instance file. To convert the rainfall in a proper unit (from 0.1 mm per 6 hour to mm/hr for example) it is also required to configure a Unit Conversion file.
ModuleConfigFiles
...
The following example of an Import Module Instance will import the time series as equidistant series for timezone GMT with a time step of 6 hours.
Code Block | ||||||
---|---|---|---|---|---|---|
| ||||||
<?xml version="1.0" encoding="UTF-8"?> <timeSeriesImportRun ......"> <import> <general> <importType>KNMIEPS</importType> <folder>$IMPORT_FOLDER_KNMI_EPS$</folder> <failedFolder>$IMPORT_FAILED_FOLDER_KNMI_EPS$</failedFolder> <backupFolder>$IMPORT_BACKUP_FOLDER_KNMI_EPS$</backupFolder> <idMapId>IdImportEPS</idMapId> <unitConversionsId>ImportKNMIUnits</unitConversionsId> <importTimeZone> <!--EPS is in GMT--> <timeZoneOffset>+00:00</timeZoneOffset> </importTimeZone> <dataFeedId>KNMI-EPS</dataFeedId> </general> <timeSeriesSet> <moduleInstanceId>ImportKNMI</moduleInstanceId> <valueType>scalar</valueType> <parameterId>P.voorsp.ens</parameterId> <locationSetId>KNMI-EPS</locationSetId> <timeSeriesType>external forecasting</timeSeriesType> <timeStep unit="hour" multiplier="6"/> <readWriteMode>add originals</readWriteMode> <synchLevel>1</synchLevel> <ensembleId>EPS</ensembleId> </timeSeriesSet> <timeSeriesSet> <moduleInstanceId>ImportKNMI</moduleInstanceId> <valueType>scalar</valueType> <parameterId>P.voorsp.ctr</parameterId> <locationSetId>KNMI-EPS</locationSetId> <timeSeriesType>external forecasting</timeSeriesType> <timeStep unit="hour" multiplier="6"/> <readWriteMode>add originals</readWriteMode> <synchLevel>1</synchLevel> </timeSeriesSet> <timeSeriesSet> <moduleInstanceId>ImportKNMI</moduleInstanceId> <valueType>scalar</valueType> <parameterId>P.voorsp.det</parameterId> <locationSetId>KNMI-EPS</locationSetId> <timeSeriesType>external forecasting</timeSeriesType> <timeStep unit="hour" multiplier="6"/> <readWriteMode>add originals</readWriteMode> <synchLevel>1</synchLevel> </timeSeriesSet> <!--to let the import module know that the KNMI rainfall is an accumulative timeseries in 0.1 mm/hr that should be disaggrated and converted to for example mm/hr--> <externUnit parameterId="P.voorsp.ens" unit="0.1 mm/6hr" cumulativeSum="true"/> <externUnit parameterId="P.voorsp.ctr" unit="0.1 mm/6hr" cumulativeSum="true"/> <externUnit parameterId="P.voorsp.det" unit="0.1 mm/6hr" cumulativeSum="true"/> </import> </timeSeriesImportRun> |
IdMapFiles
...
Info |
---|
Defines mappings between KNMI and FEWS parameters and locations. |
...
Important in this configuration is the externalParameter is manipulated to identify the deterministic, control and ensemble forecasts. Therefore the import module generates automatically a suffix to the parameter ID in the import files. If the import file contains a parameter "13011" for rainfall, the import generates the next externalParameters: "13011_deterministic", "13011_control" and "13011_ensemble".
UnitConversionFile
...
Info |
---|
Defines the conversion of the units that should be applied. |
...
Important in this configuration is the externalParameter is manipulated to identify the deterministic, control and ensemble forecasts. Therefore the import module generates automatically a suffix to the parameter ID in the import files. If the import file contains a parameter "13011" for rainfall, the import generates the next externalParameters: "13011_deterministic", "13011_control" and "13011_ensemble".
Example
...
Files
See attached files