jonesEquation the user must specify the minimum h for which the method is valid (h_min ) and the a, b and c parameters - see below)
The Jones Equation is of the form:
where:
Qm = unsteady discharge
Qc = steady discharge
S0 = energy slope for steady flow
vw = wave velocity
dh/dt = rate of charge of water level in time m/day
The adjustment factor 1/S0vw day/m varies with water level. This factor is fitted by a parabolic function of h:
for h>hmin
ratingCurveTable this allows you to simply enter the pairs of q and h values.
...