Additional parameters for Liquefaction model (Sliq2D) has to be specified
...
The greyed input fields are fixed on a default value
...
Name in English | Name in Dutch | Description | Symbol | Unit | Default + decimals + (range) |
---|---|---|---|---|---|
Saturation rate | Verzadigings graad | Degree of saturation | Sr | – | 1 Fixed value |
Grid points X | Aantal rasterpunten X | Number of points in the grid in the X direction |
| – | 20 (2-100) |
Grid points Y | Aantal rasterpunten Y | Number of points in the grid in the Y direction |
| – | 20 (2-100) |
Fill holes | Vul gaten | If true, D-FLOW SLIDE considers the stable points surrounded with unstable points as unstable. |
| Boolean | True Fixed value |
...