KEYWORD 

...

KEYWORD

(version: Legitimate GEFID versions for this keyword)

#Keyword=Param1, Param2, Param3, [ Param4, [Param5]]

ParameterType of dataExplanation.
Param1intAn integer number. At least 2 bytes. A maximum value may be required: Maximum = 250
Param2stringA sequence of alpha numerical characters. A maximum length may be required:  Maximum 80 characters. 
Param3doubleA floating point number of at least 8 bytes long. 
Param4floatA floating point number of at least 4 bytes long.  Optional, since it is between [ ].
Param5longAn integer number of at least 4 bytes. A maximum value may be required: Maximum =  100 000. Optional, since it is between [ ].

...

  • The legitimate versions of the GEFID for this keyword are listed in the same line as the caption for Keyword. For an explanation about versions, see versions.
  • Type of Data lists the minimum type of variable to hold the information in the field. For examples and restrictions for "Type of data", see the table of datatypes.
  • Strings as in Param3 must obey the rules as stated for information fields, see special characters.
  • Param4 is in between brackets. It is optional, so it may be omitted.
  • Param5 is optional. The brackets around Param5 are nested within the brackets of Param4. This means that if Param4 is omitted, Param5 should be omitted as well.
  • Valid examples for use of Keyword are:
    • #Keyword=12, The number PI, 3.141592653589793238, 3.1415926, 98765
    • #Keyword=12, The number PI, 3.141592653589793238, 3.1415926
    • #Keyword=12, The number PI, 3.141592653589793238

_________________________________________________________________________________________________________________________________________

ANALYSISCODE
Anchor

...

Analysiscode

...

Analysiscode

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Analysiscode=Code, Release, Version, Update[, Reference]

...

Note. Via this keyword, a program can determine whether the data is suitable for analysis using this version of the program. This prevents a program designed to work out, for example, a dry critical density test from importing data from a compression test. In addition, tests which still need to be analysed using an older version, can be processed using the most suitable method.

 

ANALYSISTEXT
Anchor
Analysistext
Analysistext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Analysistext=Index, Text[, Information]

...

Example: #Analysistext=129, Cohesion calculated in accordance with NEN, comments.

 

ANALYSISVAR
Anchor
Analysisvar
Analysisvar

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Analysisvar=Index, Value, Unit, Quantity

...

Example: #Analysisvar=129, 1.33,-,over-relax factor for creep.

 

CHILD

...

Anchor
Child

...

Child

(version:  1,1,0 / 2,0,0)

#CHILD= Index, Reference[, value, Unit, Quantity[, Quantity number[, Explanation]]]

...

  • Child is only listed in files of tests during which other tests are performed; e.g. child is listed in GEF-CPT-Report.
  • The reference item in the child keyword must hold an unique identifier as a link to the child. It is usually a name of a file. Other possibilities are objectids or a primary key in a database. The reference field may contain up to 1023 characters. This item is compulsory.
  • When files are transferred between different clients, one should avoid using path names, since there is no guarantee for a unique directory structure.
  • The items Value, Unit and Quantity are optional. They form a group of items. If a Value is given, the Unit and Quantity must be given as well. The reason is, that if Unit is omitted, it is impossible to know what the Value really means. Unit and Quantity are conditionally compulsory. If a value without a dimension is to be listed, e.g. merely a number, Unit is marked by '-'. For each type of value a description for Quantity can be given: e.g. a number of a scan, a depth or a date (20000419)
  • The item Quantity number is optional. It allows for an automatic recognition of the type of test. If Value, Unit and Quantity are not listed, Quantity number can not be listed as well.
  • The item Explanation is optional. If the Quantity number is not listed, Explanation can not be listed either.

 

 

...

COLUMN

COLUMN
Anchor
Column
Column

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Column=Column

ColumnintA number between 1 and 250. This gives the number of columns which are in the data block.

...

Note. For a binary file, it is assumed that #Column observations, consisting of 4-bytes floating point numbers, belonging to a scan, are stored. Also see Datatype.

 

COLUMNINFO
Anchor

...

Columninfo

...

Columninfo

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Columninfo =Column, Unit, Quantity[, Qnumber]

...

Example: #Columninfo=3, kPa, deviator pressure, 1001.

 

 

...

COLUMNMINMAX

COLUMNMINMAX
Anchor
Columnminmax
Columnminmax

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Columnminmax=Column, Min, Max

...

Example: #Columnminmax=5, 0.17, 5.68.

 

COLUMNSEPARATOR

...

Anchor
Columnseparator

...

Columnseparator

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Columnseparator=Char

CharcharThis is a character (to be printed in ASCII) which will be printed between each column, making it easier to import data with so-called spreadsheet programs or databases. See also Recordseparator.

 

Example: #Columnseparator=;

Remark: the characters \#=+-.,DEGdeg0123456789 are not allowed as columnseparator. Furthermore Columnseparator and Recordseparator must differ.

 

COLUMNTEXT

...

Anchor
Columntext

...

Columntext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Columntext=State[, Remarks]

...

 

Example: #Columntext=1.

 

COLUMNVOID
Anchor

...

Columnvoid

...

Columnvoid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#ColumnVoid=Column, Value

...

Note. Instead of using a letter of a word, it was decided to define a figure to indicate that no suitable information is present at the position, so the possibility of using the columnvoid keyword in binary data blocks was not blocked.

 

 

...

COMMENT

COMMENT
Anchor
Comment
Comment

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Comment=Text

TextstringOptional random text, not necessary for the test, rather an annotation but as a marginal note. A maximum of 1500 comment lines can be stored. Maximum 255 characters.

...

Example: #Comment=Repeat of the test of 1995-06-25.

 

COMPANYID
Anchor

...

Companyid

...

Companyid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Companyid=Name, Taxcode, CountryID

...

Example: #Companyid=GEODELFT, 8000.97.476.B.01, 31.

 

...

DATAFORMAT

DATAFORMATo
Anchor
Dataformat
Dataformat

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Dataformat=Type

TypestringText stating whether the readings in the data block are stored as an ASCII or BINARY file.

...

Note. Only ASCII and BINARY are permitted. Binary data storage can be imported and processed extremely rapidly. It is, however, system dependent. The data format default value is ASCII. Also see keyword OS.

 

 

...

DATATYPE

DATATYPE
Anchor
Datatype
Datatype

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Datatype=Type

TypestringText stating which type of numbers are stored in the data block.

...

Type

Description

Number of bytes

Example

byte

flag

1

1

int2

integer number

2

-30000

long

integer number

4

2123456789

int4

integer number

4

2123456789

real4

decimal number

4

-3.14159

float

decimal number

4

-3.14159

real8

decimal number

8

6.62×10-34

double

decimal number

8

6.62×10-34

string

text

variable

Measurement

 

EOH
Anchor

...

Eoh

...

Eoh

(version: 1,0,0 / 1,1,0 / 2,0,0)

#EOH=

 

Example: #EOH=

Note. This keyword has no data behind the  =  character which needs to be used. In addition, this keyword is completed using a Line Feed (Unix) or the Carriage Return and the Line Feed (DOS). When using binary data, no text in the data block is allowed.

 

EQUIPMENT

Anchor
Equipment
 

...

Equipment

(version: 1,0,0 / 1,1,0)

#Equipment=Text

TextstringText stating the name of the equipment.

...

Example: #Equipment=TS200.

 

FILEDATE

...

Anchor
Filedate

...

Filedate

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Filedate=Yyyy, Mm, Dd

YyyyintYear, when the file was created. Y2k compliant.
MmintMonth, when the file was created.
DdintDay, when the file was created.

...

Example: #Filedate=1995,02,20.

 

FILEOWNER
Anchor

...

Fileowner

...

Fileowner

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Fileowner=Fileowner

FileownerstringText stating the owner of the file. The file owner is responsible for the quality of the file. He/she is usually the same person who performed the test.

...

Example: #Fileowner=Lambert Smidt.

 

 

...

FILINGCODE

FILINGCODE
Anchor
Filingcode
Filingcode

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Filingcode=Code, Release, Version, Update[, Reference]

...

Example: #Filingcode=B17, 3, 0, 1, NEN888888.

 

 

...

FILINGTEXT

FILINGTEXT
Anchor
Filingtext
Filingtext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Filingtext=Index, Text[, Information]

...

Example: #Filingtext=129, Archiving in Oracle table PROJECT, tablename.

 

FILINGVAR
Anchor

...

Filingvar

...

Filingvar

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Filingvar=Index, Value, Unit, Quantity

...

Example: #Filingvar=133, 0.45, -,Location of the map.

 

 

 

FIRSTSCAN

Anchor
Firstscan
Firstscan

(version: 1,0,0 / 1,1,0)

#Firstscan=Rownumber

RownumberlongThe number of the first scan containing a meaningful value.

 

Example: #Firstscan=13.

 

 

...

GEFID

GEFID
Anchor
Gefid
Gefid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#GEFID=Release, Version, Update

...

Note. This keyword must be the first one to appear in the file. It must be written in capital letters. Using the first line, operation systems like Unix are able to deduce the type of file and which program or printer is needed to control the file.

 

LANGUAGE
Anchor

...

Language

...

Language

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Language=Language

LanguagestringAbbreviation which states the language. Maximum 2 characters.

...

Note. This keyword can influence the program which imports and analyses a GEF file. Default value is  NL .

 

LASTSCAN

Anchor
Lastscan
 

...

Lastscan

(version: 1,0,0 / 1,1,0)

#Lastscan=Rownumber

RownumberlongNumber of the last meaningful scan.

...

Note. The default value is 2147483648 (=231). (Nov 2000 I) The scans following the scan number in lastscan, are not processed.

 

MEASUREMENTCODE
Anchor

...

Measurementcode

...

Measurementcode

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Measurementcode=Code, Release, Version, Update[, Reference]

...

Example: #Measurementcode=Cu, 3, 1, 0, 300-1-CU.

 

MEASUREMENTTEXT
Anchor

...

Measurementtext

...

Measurementtext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Measurementtext=Index, Text[, Information]

...

Example: #Measurementtext=129, Temperature measured in accordance with NEN, temp. measurement.

 

 

...

MEASUREMENTVAR

MEASUREMENTVAR
Anchor
Measurementvar
Measurementvar

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Measurementvar=Index, Value, Unit, Quantity

...

Note. Measurementvar is used to store one-time measurements which form part of a test, such as temperature outside.

 

OBJECTID

...

Anchor
Objectid

...

Objectid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Objectid=Value

ValuelongReference to a number in the archive where this GEF file belongs.

...

Note. Objectid can refer to a (primary ) key in a database.

  

OS

Anchor
OS
OS

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Os=Type

TypestringText stating for which operating system the data are stored. Maximum 10 characters.

...

In the old days most Unix's were running on the generic type Motorola processors, which use Big Endian notation. DOS was running on the generic type of Intel processors, which use Little Endian representation. In the third column of Table 6 the number 16 is written down as a long integer, in hexadecimal notation.

 

 

...

PARENT

PARENT
Anchor
Parent
Parent

(version: 1,1,0 / 2,0,0)

#PARENT= Reference[, value, Unit, Quantity[, Quantity number[, Explanation]]]

...

  • Parent is only listed in files, which report tests that are performed as part of another test; e.g. parent will appear in a dissipation test.
  • The reference item in the parent keyword must hold an unique identifier as a link to the parent test. It is usually a name of a file. Other possibilities are objectids or a primary key in a database. The reference field may contain up to 1023 characters. This item is compulsory.
  • When files are transferred between different clients, one should avoid using path names, since there is no guarantee for a unique directory structure.
  • The items Value, Unit and Quantity are optional. They form a group of items. If a Value is given, the Unit and Quantity must be given as well. The reason is, that if Unit is omitted, it is impossible to know what the Value really means. Unit and Quantity are conditionally compulsory. If a value without a dimension is to be listed, e.g. merely a number, Unit is marked by '-'. For each type of value a description for Quantity can be given: e.g. a number of a scan, a depth or a date (20000419)
  • The item Quantity number is optional. It allows for an automatic recognition of the type of test. If Value, Unit and Quantity are not listed, Quantity number can not be listed as well.
  • The item Explanation is optional. If the Quantity number is not listed, Explanation can not be listed either.

 

PROCEDURECODE

Anchor
Procedurecode
Procedurecode

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Procedurecode=Code, Release, Version, Update[, Reference]

...

Example: #Procedurecode=GEF-CPT-Report, 1,0,0.

 

PROJECTID
Anchor

...

Projectid

...

Projectid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Projectid=Type,[ Number,[ Sub]]

...

Example: #Projectid=CO, 342770, 624.

 

 

...

PROJECTNAME

PROJECTNAME
Anchor
Projectname
Projectname

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Projectname=Projectname

ProjectnamestringText stating the name of the relevant project. Maximum of 255 characters.

...

Example: #Projectname= High Speed Line.

 

QNMINMAX

Anchor
 
Qnminmax

...

Qnminmax

(version: 2,0,0)

#Qnminmax=Qn, Min, Max

QnlongThe quantity number to which the information relates.
MindoubleMinimum value in the column associated with this quantity number.
MaxdoubleMaximum value in the column associated with this quantity number.

...

Example: #Qnminmax=3019, 0.17, 5.68.

 

QNTIME

Anchor
Qntime
 

...

Qntime

(version: 2,0,0)

#Qntime=Qn[, Timecode[, Unit]]

...

Table 7     Value of Code and Unit  

 

Timecode

Unit

1

second

2

minute

3

hour

4

day

5

week

 

QNVOID

Anchor
Qnvoid
Qnvoid

(version: 2,0,0)

#QnVoid=Qn, Value

QnlongThe quantity number to which the information relates.
ValuedoubleThe figure which shows that the value does not contain suitable information.

...

Note. Instead of using a letter of a word, it was decided to define a figure to indicate that no suitable information is present at the position, so the possibility of using the qnvoid keyword in binary data blocks was not blocked.

 

RECORDSEPARATOR

Anchor
 
Recordseparator

...

Recordseparator

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Recordseparator=Char

CharcharThe character used to finish a data record. A data record always consists of a fixed number of registrations (the value is given by the #column). It is the physical end of the scan. Also see Columnseparator.

...

(Nov 2000 I) Remark: the characters \#=+-.,DEGdeg0123456789 are not allowed as columnseparator. Furthermore Columnseparator and Recordseparator must differ.

 

REPORTCODE

...

Anchor
Reportcode

...

Reportcode

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Reportcode=Code, Release, Version, Update[, Reference]

...

Example: #Reportcode=Standard, 3, 1, 0, 300-1-SDS.

 

 

REPORTDATAFORMAT

...

Anchor
Reportdataformat

...

Reportdataformat

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Reportdataformat=Layout

Layoutstring

The layout of the values to be printed sLayout consists of a series of words, separated by blanks. The number of words must be equal to the number of columns, as started in #COLUMN=. Each word consists of one letter and one or more digits. This word determines how a value is printed. The convention of the FORTRAN format identifier is used:

InInteger, n digits long.
Fw.dFloating point number, w digits long, d decimals.
Ew.dExponential representation, w digits long, d decimals.

...

Example: #Reportdataformat=F7.3 F7.3 E11.4 I6.

 

 

 

...

REPORTTEXT

REPORTTEXT
Anchor
Reporttext
Reporttext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Reporttext=Index, Text[, Information]

...

Example: #Reporttext=129, Section 5 is confidential, general comment.

 

 

REPORTVAR
Anchor

...

Reportvar

...

Reportvar

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Reportvar=Index, Value, Unit, Quantity

...

Example: #Reportvar=17, 66, -, number of pages.

 

 

...

ROW

ROW

Anchor
Row
Row

(version: 2,0,0)

#Row=Rows

RowslongA number between 1 and 2147483647. This gives the number of rows which are in the data block.

 

Example: #Row=1495.

 

SCANFREQ
Anchor

...

Scanfreq

...

Scanfreq

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Scanfreq=Value, Startrow

...

Note. The scan frequency is expressed in Hz (s-1).

 

SCANTIME

...

Anchor
Scantime

...

Scantime

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Scantime=Value, Startrow

...

Note. The time interval is expressed in s. In the example, a reading is carried out each minute. For scanfreq and scantime, startdate and starttime are to be used. The scans in the test are thus placed in absolute form in time.

 

 

...

SETUPCODE

SETUPCODE

Anchor
Setupcode
Setupcode

(version: 2,0,0)

#Setupcode=Code, Release, Version, Update[, Reference]

...

Example: #Setupcode=S17, 3, 0, 1, NEN888888.

 

SETUPTEXT

Anchor
 
Setuptext

...

Setuptext

(version: 2,0,0)

#Setuptext=Index, Text[, Information]

...

Example: #Setuptext=250, Removing carbonates by H2SO4, carbonate removal.

  

SETUPVAR

Anchor
 
Setupvar

...

Setupvar

(version: 2,0,0)

#Setupvar=Index, Value, Unit, Quantity

...

Example: #Setupvar=250, 45.89, g, Mass of removed carbonates.

 

SPECIMENCODE

...

Anchor
Specimencode

...

Specimencode

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Specimencode=Code, Release, Version, Update[, Reference]

...

Example: #Specimencode=MN, 3, 1, 0, 300-1-Mons.

 

SPECIMENTEXT
Anchor
Specimentext
Specimentext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Specimentext=Index, Text[, Information]

...

Example: #Specimentext=129, Sample fell apart during transportation, general comment.

...

 

SPECIMENVAR
Anchor
Specimenvar
Specimenvar

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Specimenvar=Index, Value, Unit, Quantity

...

Note. Specimenvar is very similar to Measurementvar as far as structure and use are concerned. The difference is that the information is specifically related to a sample with Specimenvar, while Measurementvar is concerned with quantities which are specifically related to measuring and measurement apparatus where appropriate.

 

STARTDATE

...

Anchor
Startdate

...

Startdate

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Startdate=Yyyy, Mm, Dd

YyyyintThe year in which the test started. Y2k compliant.
MmintThe month in which the test started.
DdintThe day on which the test started.

...

Note. Together with the start time, the start date is important for tests as a function of time.

 

STARTTIME
Anchor

...

Starttime

...

Starttime

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Starttime=Hour, Min, Sec

...

Example: #Starttime=12, 35, 24.75.

 

STRUCTURETEXT
Anchor

...

Structuretext

...

Structuretext

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Structuretext=Codeword, Parameter1[, Parameter2[, Parameter3[,,]]]

...

Example: #Structuretext=GEFID, Releasenumber, Versionnumber, Updatenumber.

 

STRUCTURETYPE
Anchor
Structuretype
Structuretype

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Structuretype=Codeword, Type1[, Type2[, Type3[,,]]]

...

Example: #Structuretype=GEFID, int2, int2, int2.

 

TESTID
Anchor

...

Testid

...

Testid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Testid=TestID

TestIDstringText stating which test from a series of tests this file concerns.

 

Example: #Testid=T13B.

 

 

...

TIMECOLUMN

TIMECOLUMN
Anchor
Timecolumn
Timecolumn

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Timecolumn=Column[, Timecode[, Unit]]

...

Table 8     Value of Code and Unit 

 

 

Timecode

Unit

1

second

2

minute

3

hour

4

day

5

week

 

XYID

...

Anchor
Xyid

...

Xyid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#XYid=MapID, X, Y[, EpsX, EpsY]

...

The MapID code consists of the international dial code for a specific country, multiplied by 1000, followed by a number 000 .. 999. 

 

ZID
Anchor

...

Zid

...

Zid

(version: 1,0,0 / 1,1,0 / 2,0,0)

#Zid=ReferenceID, Z[, EpsZ]

...