What

pi-ratingCurves_ratingcurves.xml

Description

Configuration for rating curves at specific locations

schema location

httphttps://fewsfewsdocs.wldelftdeltares.nl/schemas/version1.0/pi-schemas/pi_ratingcurves.xsd

Entry in ModuleDescriptors

<moduleDescriptor id="Transformation">
<description>General transformation Component</description>
<className>nl.wldelft.fews.system.plugin.transformation.TransformationModule</className> </moduleDescriptor>

...

Configuration

 The The transformation stageDischarge/ratingCurve uses rating curves according to the schema pi-_ratingcurves.xsd. It is possible to store the ratingcurves in a ratingCurves.xml file in the regionConfig directory. However it is recommended to store the ratingCurves in the FEWS database as time series. The ratingCurves can be imported in the FEWS database by using a dedicated import which is capable of importing rating curves from file as long as the file is compliant with the pi-ratingCurves.xsd schema. 

Rating curves can be stored  in the folder RegionConfigFiles  in the file RegionConfig.xml , or  can be imported  in the FEWS database  with  TimeSeriesImport module,  import type “pi_ratingcurves”

Rating Curve schema

The schema of the pi-ratingcurves can be found at: httphttps://fewsfewsdocs.wldelftdeltares.nl/schemas/version1.0/pi-schemas/pi_ratingcurves.xsd

Header

The header element contains the metadata about the rating curve. Below an overview of the available elements.

  • locationId: The location id for which the rating curve is valid
  • qualifierIdThe allows the configurator to add 1 or more qualifier to the definition of the rating curve. This is useful when for 1 location more rating curves are valid. The locationId and the configured qualifiers define the id of the rating curve.
  • startDate: This element defines when the rating curve becomes active.
  • endDate:  This (optional) element defines until when the rating curve is active.
  • longName: Optional descriptive name
  • stationName: Optional station name
  • stageUnit:  Definition of the stage unit
  • dischargeUnit: Definition of the discharge unit
  • comment: This section allows to define a (optional comment) for the rating curve. If a comment is defined the comment will be shown in the TimeSeriesDialog when viewing the rating curve.
  • creationDate: The date on which the rating curve was created.
  • creationTime: The time on which the rating curve was created.
  • region: The description of the region. This is needed when the id of the rating curve is the same in different regions.
  • properties:  Optional properties  of the rating curve

Table

The table contains the actual description of the Table rating curve.

...

To show the stageToDischargePowerEquation rating curves in the TimeSeriesDisplay, a table is generated on the fly from the power equations.
For each equation ten stage values are generated using increment (max stage – min stage) /10 , and for each stage a discharge is computed. Please note that this table is only used in the display and not in TransformationModule computations.

...