Output
To make sure the amount of output produced by SOBEK is no more than needed, it is important to uncheck all unnecessary output creation. If only water depth is needed in 2D then only have this option checked.
Settings inside the SOBEK module directory
...
variable | required | default value | meaning | example | |
version | yes | Version of Batch Data Structure | 2 | ||
projectDir | yes | SOBEK project directory | BosRegge.lit | ||
caseName | yes | Case name as in SOBEK project | Basismodel voor voorspelinstrument 101105, WL 20060404 | ||
showTablesFlipped | no | FALSE | Option to show all the input and output tables in the user interface flipped (true=horizontal, false = vertical) | TRUE | |
resultsHisFile | no |
| Output filename | Output\Output.his | |
dataPath | no | Path where all kind of info files are stored | Output | ||
resultsSaved | no | FALSE | If the results have been saved and are availalbe | TRUE | |
parInfoFile | no |
| Filename of file with parameter information | Output\Output_par.csv | |
storeWorkDir | no | FALSE | Option to save the complete working directory | FALSE | |
workDirStored | no | FALSE | Option to determine if working directory has been saved | FALSE | |
storeOutputInOneFile | no | FALSE | Option to save all the output in one output file, which is required for FEWS | TRUE | |
storeFEWSState | no | FALSE | Option to save state information, which is required for FEWS | TRUE | |
fewsDiagnosticsFile | no |
| Filename of FEWS diagnostics file | Logs\Diagnostics.xml | |
clearWorkingDirectories | no | TRUE | Option to clear working directory after running the simulation | FALSE | |
skipTimeSteps | no | 0 | Number of timesteps to be skipped when converted FEWS ASCII Meteo file to Bui file. | 0 | |
useXMLBinFileType | no | FALSE | Option to write Delft-FEWS PI files with binary data section. Improves performence very much, but bad to check the contents of the PI files. Only use this if everything is going right..... | TRUE | |
useParsenUpdateMode | yes | FALSE | Option to let the PARSEN of the Flow modules only update the time series in the NEFIS files. Might improve performence very much, but does not pick up any other updated data from the MDB Files | FALSE | |
parsenMinimumTimeSeriesLength | yes | 1000 | If useParsenUpdateMode is TRUE, it is required to define the number of timesteps to generate in the time series tables. Value must be higher than zero. | 1000 | |
parsenSourceFiles | yes | If useParsenUpdateMode is TRUE, the source files which should be updated by the PARSEN must be defined here. | Defaults\sobek.* |
...
Please note that the rainfall, evaporation and , wind, wqmeteo time series should be all in one separate single XML file, so one for all rainfall series, one for all evaporation series and one for all wind series (speed and direction both in one file).
Rainfall series are always converted independent on the parameterID, where all locationIDs are converted to meteo stations. Evaporation works the same. Regarding wind series, the adapter looks for the following time series:
...
The adapter software is installed as part of the SOBEK installation in the Programs folder. However, due to various features extensions, a later version of the SbkBatch.exe (and the corresponding sobekAdvancedBatchcorresponding sobekAdvancedBatch.xsd) can be needed. Therefore the latest version of both can be found here:
...