Info | ||
---|---|---|
| ||
In the ImportActivities the state files and the timeseries can be imported to Delft-FEWS. It is important to convert the extension of the state files before you import it to Delft-FEWS, this can be done by adding the </relativeExportFile> to your configuration. |
Improved DIMR adapter
Code Block | ||||
---|---|---|---|---|
| ||||
<?xml version="1.0" encoding="UTF-8"?>
<Run xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.wldelft.nl/fews/PI" xsi:schemaLocation="http://www.wldelft.nl/fews/PI http://fews.wldelft.nl/schemas/version1.0/pi-schemas/pi_run.xsd" version="1.5">
<timeZone>0.0</timeZone>
<startDateTime date="2017-03-26" time="06:00:00"/>
<endDateTime date="2017-03-29" time="06:00:00"/>
<time0 date="2017-03-26" time="06:00:00"/>
<workDir>X:\XXX\DimrPreAdapterTest\piRunFile1d2dRTC\dimr_model</workDir>
<inputTimeSeriesFile>X:\XXX\piRunFile1d2dRTC\Input\export_pi_flow1d.xml</inputTimeSeriesFile>
<inputTimeSeriesFile>X:\XXX\piRunFile1d2dRTC\Input\export_pi_fm.xml</inputTimeSeriesFile>
<inputTimeSeriesFile>X:\XXX\piRunFile1d2dRTC\Input\export_pi_fbc.xml</inputTimeSeriesFile>
<outputDiagnosticFile>notUsed.xml</outputDiagnosticFile>
<properties>
<!-- Reference to dimr configuration file, relative to parent directory of the/this pi-run.xml file -->
<!-- This file will be read to see which components of the dimr are used and find references to .md1d, .mdu, flow1d2d.ini and/or fbc runtime config -->
<string key="dimrConfigFile" value="../dimr_config.xml"/>
<!-- Specify which of the above time series xml files is meant for flow1d -->
<string key="piFileForFlow1d" value="inputTimeSeriesFile-1"/>
<!-- Specify which of the above time series xml files is meant for FM -->
<string key="piFileForFm" value="inputTimeSeriesFile-2"/>
<!-- Specify which of the above time series xml files is meant for FBC (rtc1) -->
<string key="piFileForFbc" value="inputTimeSeriesFile-3"/>
</properties>
</Run>
|