Below the schema of the timeseries modifier.
Code Block | ||||
---|---|---|---|---|
| ||||
<complexType name="TimeSeriesModifierComplexType">
<complexContent>
<extension base="fews:ModifierBaseComplexType">
<sequence>
<element name="timeSeries" type="fews:TimeSeriesFilterComplexType" minOccurs="0" maxOccurs="unbounded"/>
<element name="softLimits" type="fews:SoftLimitsComplexType" minOccurs="0"/>
<element name="hardLimits" type="fews:HardLimitsComplexType" minOccurs="0"/>
<element name="defaultStartTime" type="fews:DefaultStartTimeEnumStringType">
<annotation>
<documentation>Start of time period to which modifier is applied.
When omitted this value will default to the Year 1000 and will be disabled.
</documentation>
</annotation>
</element>
<element name="offsetDefaultStartTime" type="fews:TimeShiftComplexType" minOccurs="0"/>
<element name="defaultEndTime" type="fews:DefaultEndTimeEnumStringType">
<annotation>
<documentation>End of time period to which modifier is applied.
When omitted this value will default to the Year 3000 and will be disabled.
</documentation>
</annotation>
</element>
<element name="offsetDefaultEndTime" type="fews:TimeShiftComplexType" minOccurs="0"/>
<element name="defaultValidTime" type="fews:emptyElement" minOccurs="0">
<annotation>
<documentation>Forecast time after which the modifier is no longer valid.
When omitted this value will default to the Year 3000 and will be disabled.
</documentation>
</annotation>
</element>
<element name="resolveInWorkflow" type="boolean">
<annotation>
<documentation>search for timeseries in the currently selected workflow. In a IFD environment the selected topology node will provide the selected workflow</documentation>
</annotation>
</element>
<element name="resolveInPlots" type="boolean">
<annotation>
<documentation>search for timeseries in the plots of the currently selected topology node</documentation>
</annotation>
</element>
<element name="editInPlots" type="boolean" default="true" minOccurs="0">
<annotation>
<documentation>Allow to graphically create time series modifiers in the plot display. If this option is disabled, it is only allowed to create this modifier in the modifier display</documentation>
</annotation>
</element>
<element name="createContinousModifiers" type="boolean" default="true" minOccurs="0">
<annotation>
<documentation>if this option is disabled and a modifier is graphically created in the plot display, for each continous period of changes a modifier is created.
By default for each editting sequence a modifier will be created.</documentation>
</annotation>
</element>
</sequence>
</extension>
</complexContent>
</complexType>
|
...