Unknown macro: {import}

Group 4: Benchmarks generated by the program itself

This section contains tests for which the reference results are generated with D-FLOW SLIDE.

4.1 Test on the level indicator

Description

To check that the level indicator is correctly inputted in D-FLOW SLIDE, the results of the two following calculations should lead to the same results:

  • Benchmark 4-1a uses the same input as benchmark 1-1a, refer to paragraph 1.1 in group 1.
  • Benchmark 4-1b uses the same input as benchmark 4-1a except that the Z-coordinates of the geometry are shifted by -20 m so that all points have a negative Z-coordinate.
D-FLOW SLIDE results

4.2 Test on the units

Description

In the Units tab of D-FLOW SLIDE, it is possible to specify the unit of different parameters:

  • Fraction: -, %, o/oo or ppm
  • Length: m, mm, cm, inch, ft or km
  • Tiny length: xxxm
  • Angle: deg, rad, grad, tan or cot
  • Weigth: kN/m3, N/m3, lb/in3, MN/m3, lb/ft3
  • Pressure: kN/m2, N/m2, Pa, kPa, MPa, kN/cm2, psi
  • Permeability: m/s, m/min, m/hr, m/day

To test the correctness of the convertion , 7 benchmarks are created using the following set of units:

Benchmark name

Fraction unit

Length unit

Tiny length unit

Angle unit

Weigth unit

Pressure unit

Permeability unit

bm4-2a

m

xxxm

deg

kN/m3

kN/m2

m/s

bm4-2b

%

mm

xxxm

rad

N/m3

N/m2

m/min

bm4-2c

o/oo

cm

xxxm

grad

lb/in3

Pa

m/hr

bm4-2d

ppm

inch

xxxm

tan

MN/m3

kPa

m/day

bm4-2e

ft

xxxm

cot

lb/ft3

MPa

m/s

bm4-2f

km

xxxm

deg

kN/m3

kN/cm2

m/s

bm4-2g

m

xxxm

deg

kN/m3

psi

m/s

  • No labels