You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Input

  • observedDischarge
  • simulatedInstantaneousDischarge

Coefficient set

  • blending steps
  • interpolations type

Output

  • adjustedForecastDischarge

Description

 AdjustQUsingObservedInstantaneousDischarge

This procedure uses an observed instantaneous discharge to correct a simulated discharge. If there is an observed value for a certain time step then that
value will be used instead of the simulated value. If there is no observed data is available the correction procedure will calculate a value or in some cased use simulated value.

The configuration has two configuration options which will influence the behaviour of the correction procedure. The first one is blending steps. If there is a gap in the observed data which is
a time steps large and a < blending steps then the output values for the gap will be determined using an interpolation procedure. If a >= blending steps then a blend procecure will be used to
fill the gap.

Interpolation procedure
The second configuration option which influence the behaviour of the correction procedure is the interpolation type. Two options are available:ratio and difference.
To calculate the value of the adjusted time series a correction procedure is used for the simulated discharge. For

  • No labels