Input
- observedDischarge
- simulatedInstantaneousDischarge
Coefficient set
- blending steps
- interpolations type
Output
- adjustedForecastDischarge
Description
 AdjustQUsingObservedInstantaneousDischarge
This procedure uses an observed instantaneous discharge to correct a simulated discharge. If there is an observed value for a certain time step then that
value will be used instead of the simulated value. If there is no observed data is available the correction procedure will calculate a value or in some cased use simulated value.
The configuration has two configuration options which will influence the behaviour of the correction procedure. The first one is blending steps. If there is a gap in the observed data which is
a time steps large and a < blending steps then the output values for the gap will be determined using an interpolation procedure. If a >= blending steps then a blend procecure will be used to
fill the gap.
Interpolation procedure
The second configuration option which influence the behaviour of the correction procedure is the interpolation type. Two options are available:ratio and difference.
To calculate the value of the adjusted time series a correction procedure is used for the simulated discharge. For