NOTE: in the current version of the program, it is not checked if the thickness is minimal 5 m. The average is performed over a thickness of 5 m, by not taking into account the none-sandy layers.

Step 7: Is

...

breaching possible?

This criterion corresponds to step 5 of CUR Aanbeveling 113, 2008.

...

If so then the slope is breaching sensitive, so the check FAILED, so a Detailed check is needed. In the case the slope height is over 40 m a Detailed check is also needed.

if not then the check SUCCEDDEDSUCCEEDED.

 

Different cases are considered to determine the critical slope:

  • a slope with or without  flat banks
  • for medium fine sand with   D50 > 200 μm and D15 > 100 μm
  • for sand with coarse sand and gravel with   D50 > 500 μm and D15 > 250 μm

...

 (a) In D-Flow Slide, the ground surface level (GL) (maaiveld in Dutch) is the lowest level between the water level and the top of the channel slope (called "Insert river channel").

...