This check should be performed only if the damage criterion (step 1a) is not met (i.e. a flow slide does not lead to damage). The result of this check will not lead to failure of not result in a "failure" in the safety assessment, but is an indication that maintenance work is requiredbut only indicates that the slope protection may become unstable

Step 1c: Artificially underwater installed and non-compacted sandy foreland ?

...

NOTE: Only the case "without flat blankshorizontal steps" is implemented in D-Flow Slide.

...

Table A.4.2a from CUR113b, profile without flat bermshorizontal steps:

from depth
[m +GL(a)]

 to depth z
[m +GL(a)]

Average slope 

   
  

Medium fine sand

D50 > 200 μm and D15 > 100 μm

Coarse sand/Gravel

D50 > 500 μm and D15 > 250 μm

   Local slopeAverage slope 0 - z  Local slopeAverage slope 0 - z 

0

 -5

1:2

1:21:2 1:2 

-5

 -10

1:3

1:2.5

-10

 -15

1:4

1:31:3 1:2.5 

-15

 -20

1:5

1:3.5
 -20 -251:61:41:4 1:3 
 -25 -301:81:4.67
 -30 -351:101:5.431:6 1:3.75 
 -35 -401:101:6

...