Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

Display groups may be defined while DELFT-FEWS is running and reloaded by re-opening the time series dialogue.
If a mistake is made, then the shortcuts item to open the tree view will not appear and an appropriate message will be generated. After resolving the mistake the item will again become available on re-loading the display.

subplot (plot

...

)

Element of plot. Root element for each subplot. Multiple sub-plots may be defined per plot.

...

Code Block
languagexml
titleadditionalTimeSeries example (click to expand)
linenumberstrue
collapsetrue
	<plot id="WATERBALANS_DAG_CAW">
		<subplot stackPlot="true">
			<lineStyle>bar</lineStyle>
			<timeSeriesSet>
				<moduleInstanceId>BalansAfvoergebieden</moduleInstanceId>
				<valueType>scalar</valueType>
				<parameterId>H.G.i.d</parameterId>
				<locationSetId>AFVOERGEBIEDEN</locationSetId>
				<timeSeriesType>external historical</timeSeriesType>
				<timeStep unit="day" timeZone="GMT+1"/>
				<relativeViewPeriod unit="day" start="-32" end="0"/>
				<readWriteMode>read only</readWriteMode>
			</timeSeriesSet>
			<additionalTimeSeries name="*AFGB_NAAR*" separateSubPlot="true">
				<locationFunctionEquals selected="@LOC_ID@" additional="@AFGB_NAAR@"/>
				<timeSeriesSet>
					<moduleInstanceId>ImportOpvlWater</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>Q.G.15</parameterId>
					<locationSetId>OPVLWATER_SUBLOC_DEBIETEN</locationSetId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="minute" multiplier="15"/>
					<relativeViewPeriod unit="hour" start="-70" end="0"/>
					<readWriteMode>read only</readWriteMode>
				</timeSeriesSet>
			</additionalTimeSeries>
			<additionalTimeSeries name="*AFGB_VAN*" separateSubPlot="true">
				<locationFunctionEquals selected="@LOC_ID@" additional="@AFGB_VAN@"/>
				<timeSeriesSet>
					<moduleInstanceId>ImportOpvlWater</moduleInstanceId>
					<valueType>scalar</valueType>
					<parameterId>Q.G.15</parameterId>
					<locationSetId>OPVLWATER_SUBLOC_DEBIETEN</locationSetId>
					<timeSeriesType>external historical</timeSeriesType>
					<timeStep unit="minute" multiplier="15"/>
					<relativeViewPeriod unit="hour" start="-70" end="0"/>
					<readWriteMode>read only</readWriteMode>
				</timeSeriesSet>
			</additionalTimeSeries>
		</subplot>
	</plot>

locationLoop (displayGroup

...

)

By defining a location loop within a displayGroup, the display group will be created for each location of location set configured in the loop. 

...

Code Block
languagexml
titlelocationLoop example (click to expand)
linenumberstrue
collapsetrue
	<displayGroup name="Validations Location Loop">
		<displayGroup name=" ">
			<locationLoop>
				<locationSetId>FloodingAreas</locationSetId>
				<includeChildren>true</includeChildren>
				<locationRelationId>L_AREA</locationRelationId>
				<locationRelationId>L_VISIBILIY</locationRelationId>
				<locationRelationId>MEASUREMENT_PARENT</locationRelationId>
			</locationLoop>
			<displayGroup name="Waterbalance">
				<display name="Waterbalance">
					<plotId>Waterbalance</plotId>
				</display>
				<display name="Waterbalance incl. error">
					<plotId>Waterbalance_error</plotId>
				</display>
			</displayGroup>
                           ...
		</displayGroup>
	</displayGroup>


display (displayGroup

...

)

Definition of a pre-configured display. Each display may contain multiple sub-plots. Multiple displays may be defined per display group.

...

To tie the date/time ticks to the valid times of the (cardinal) time step, configure ‘tickTimeStep’ in DisplayGroups.xml. For example, if the ‘tickTimeStep’ is 6 hours then the ticks are always aligned with the synoptic times 00Z, 06Z, 12Z, 18Z. When we are zooming out and there is no space to display all date/times along the x-axis, then one or more synoptic times ticks are omitted. For example we see ticks at 00Z and 18Z.

singleLocationDisplays (displayGroup

...

)

Adds multiple displays at once to this display group. Every display will show only one location.

...