Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The flexible distribution can be activated in the global properties, setting VERDELING_FLEX=Flex. For usual calculation: VERDELING_FLEX=. In case of flexibe distribution the following rule is used: if the discharge of Lobith is less than 1700 m3/s, the minimum discharge of the Nederrijn is equal to the discharge according to the fix distribution, the maximum is free. Above 1700 m3/s, the minimum discharge of hte Nederrijn 30 m3/s. If the discharge is more/less, it is coming 2/3 from the Waal and 1/3 from the IJssel.

QWAST versie HalfFlex (select VERDELING_FLEX=HalfFlex): the discharge of the Nederrijn is only flexibel above 1700, and only in the sense that it can be less than the fix distribution but not more.

The different options are also shown in the figure below. With blue color, the original distribution of the discharge, this data is provide to QWAST. We compare three calculations:

...