Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Purpose and use of Transformation:

Aggregates discharge volume of selected subevents in m3. This transformation can for instance be used to report statistics on sewer spillage.

Background and Exceptions:

The input must be m3/s. The output time step must be bigger than the input time step. All input values must be non-missings, otherwise the result will be set to missing value. In case one of the inputs is doubtful, the output flag is set to ORIGINAL_DOUBTFUL.

Input

discharge Equidistant measurements in m3/s.

...