Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Code Block
languagexml
titlePI-run.xml
<?xml version="1.0" encoding="UTF-8"?>
<Run xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.wldelft.nl/fews/PI" xsi:schemaLocation="http://www.wldelft.nl/fews/PI http://fews.wldelft.nl/schemas/version1.0/pi-schemas/pi_run.xsd" version="1.5">
    <timeZone>0.0</timeZone>
    <startDateTime date="2017-03-26" time="06:00:00"/>
    <endDateTime date="2017-03-29" time="06:00:00"/>
    <time0 date="2017-03-26" time="06:00:00"/>
    <workDir>X:\XXX\DimrPreAdapterTest\piRunFile1d2dRTC\dimr_model</workDir>
    <inputTimeSeriesFile>X:\XXX\piRunFile1d2dRTC\Input\export_pi_flow1d.xml</inputTimeSeriesFile>
    <inputTimeSeriesFile>X:\XXX\piRunFile1d2dRTC\Input\export_pi_fm.xml</inputTimeSeriesFile>
    <inputTimeSeriesFile>X:\XXX\piRunFile1d2dRTC\Input\export_pi_fbc.xml</inputTimeSeriesFile>
    <outputDiagnosticFile>notUsed.xml</outputDiagnosticFile>
    <properties>
		<!-- Reference to dimr configuration file, relative to parent directory of the/this pi-run.xml file -->
		<!-- This file will be read to see which components of the dimr are used and find references to .md1d, .mdu, flow1d2d.ini and/or fbc runtime config -->
        <string key="dimrConfigFile" value="../dimr_config.xml"/>
        <!-- Specify which of the above time series xml files is meant for flow1d --> 
        <string key="piFileForFlow1d" value="inputTimeSeriesFile-1"/>
        <!-- Overwrite RstInterval value in the .mdu file with this property --> 
        <string key="restartIntervalForFm" value="600"/>
        <!-- Specify which of the above time series xml files is meant for FM --> 
        <string key="piFileForFm" value="inputTimeSeriesFile-2"/>
        <!-- Specify which of the above time series xml files is meant for FBC (rtc1) --> 
        <string key="piFileForFbc" value="inputTimeSeriesFile-3"/>
        <!-- Will write the pi time series values for fbc as binary in timeseries_import.bin-->
        <string key="piTimeSeriesAsBin" value="true"/>
    </properties>
</Run>

...

In the .mdu file itself it will replace Tstart, Tstop and RstInterval with the appropriate values.

RstInterval can be overwritten by a property in the run info file called "restartIntervalForFm"

 

DFlow1D component

Will be used if library "cf_dll" is configured as component within the dimr config file

...