What |
SystemMonitorDisplay.xml |
---|---|
Required |
no |
Description |
Definitions of optional elements of the system monitor |
schema location |
http://fews.wldelft.nl/schemas/version1.0/systemMonitorDisplay.xsd |
Entry in DisplayDescriptors |
<displayDescriptor id="SystemMonitorDisplay"> |
Description
Configuration file for the optional elements of the System Monitor display. These are:
- The Import Status Tab
- The bulletin board
Configuration
importStatus
The Import Status Tab shows the last time a data type has been imported and can be colour coded based on the amount of time since the last import. An example file is attached.
description
Optional description
tabName
Required element that defines the name of the tab in the user interface.
tabMnemonic
Optional Mnemomic for the tab.
defaultTimeThreshold
Default color coding for all datafeeds. The next element (extraTimeThreshold) can override these settings per datafeed.
Each timeTreshold element (see figure above) indicates a minimum age needed to switch to a certain colour.
extraTimeThreshold
This element is similar to the defaultTimeThreshold element. Howevere, in tis case the colours are defined separately for each datafeedId.
The datafeedId is defined in the import module. If no datafeedId is configured in the Import module the directory from which the files have been imported is used.)