Edit flow measurements


Current meter data

The hymos Data Edit and Entry function 'Current meter data' allows you to add, edit and delete coefficients for a calibrated current meter instrument. The information stored includes:

Flow measurements^image049.jpg!

  • Instrument type, number, make and manufacturing date.
  • Calibration period and person who calibrated the instrument.
  • Coefficients of the current meter calibration equation and period for which the entered equation is valid (this is important for later use, HYMOS checks on these dates).
  • Remarks, text can be added in the text box showing when pressing this button.
    Press <Save> to save the entered information in the database, <Delete> to delete an equation from the database, <Close> to leave the window without saving.

    Flow Measurement Data


    Flow measurements can be added with 'flow measurement data' function from the 'Edit and Entry' function map. The data entered or edited will not be stored in the HYMOSdatabase but in separate files (extension *.flw).
    Flow measurements^image051.jpg!
    The entered data includes:
    Measurement date and time
    Duration of measurement in minutes
    Observation Number
    Unit: metric or imperial
    Computation of total flow: mean section method, or mid-section method
    distance from reference point
    width of river
    level of gauge zero
    water level (rel. to gauge zero) at start of measurement
    water level at end of measurement
    water level difference with downstream station, only required if backwater correction is required, else 0.
    vertical number, distance from reference point and water depth
    measuring depth, number of rotations duration of single point measurement
    airline length, vertical angle, horizontal angle
    To edit an existing flow measurement file, double-click on the filename text box and select a file with the windows file open dialogue.
    Add a flow measurement by filling in the text boxes and making your selection concerning the discharge computation method and units. Enter the number of verticals and per vertical the number of measuring points. After entering all values give a filename and press <Save> to save your data.
    The Layout of the flow measurements file (.flw) is as follows
    Line 1
    Position
    01 ‑ 03 number of the measurement
    04 ‑ 07 year (yyyy) +
    09 ‑ 10 month (mm) +date of measurement
    12 ‑ 13 day (dd) +
    15 ‑ 16 hour (hh) +time of measurement at start
    18 ‑ 19 minute (mi) +
    20 ‑ 22 duration of measurement in minutes
    25 unit: metric(0) or imperial(1)
    28 type of measurement:
    1‑6 = point measurements according to ISO standard, where the type number corresponds with the number of points in the vertical
    7 = point measurements with free distance between points in the vertical (number of points £10)
    8 = moving boat: method vv‑a
    9 = moving boat: method vb‑vv
    31 comp. of total flow: 1= mean section method, or
    2= mid‑section method
    Line 2 - Point velocity measurements (type £ 7).
    Position:
    01 ‑08 distance from reference point
    09 ‑16 width of river
    17 ‑24 level of gauge zero
    25 ‑32 water level (rel. to gauge zero) at start of measurement
    33 ‑40 water level at end of measurement
    41 ‑48 water level difference with downstream station, only required if backwater correction is required, else 0.
    Line 3 - Point velocity measurements (type £ 7).
    Position:
    01 ‑04 vertical number + only for first point
    05 ‑12 distance from reference point + in vertical water depth
    13 ‑20 water depth + is required, else 0.
    21 ‑25 measuring depth (relative depth for types < 7, actual depth for type = 7)
    26 ‑30 number of rotations
    31 ‑35 duration of single point measurement
    36 ‑40 airline length +
    41 ‑45 vertical angle + in case of airline length correction
    46 ‑50 horizontal angle +
    Line 2 - Moving boat (type ³ 8):
    Position
    01 ‑08 distance from reference point
    09 ‑16 width of river
    17 ‑24 width according to moving boat measurements
    25 ‑32 level of gauge zero
    33 ‑40 water level (rel. to gauge zero) at start of measurement
    41 ‑48 water level at end of measurement
    49 ‑56 current meter depth
    57 ‑63 water level difference with downstream station, only required if backwater correction is required, else 0.
    64 ‑72 coefficient in power profile
    Line 3 - Moving boat (type ³ 8)
    Position
    01 ‑04 vertical number + only for first point
    05 ‑12 distance from reference point + in vertical water depth
    13 ‑20 water depth + is required, else 0.
    21 ‑25 angle (type=8) or boat velocity (type=9)
    26 ‑30 number of rotations
    31 ‑35 duration of measurement