Transformation: |
dischargeVolume |
---|---|
Transformation Group: |
Events |
Description: |
Calculates the discharge volume by multiplying the input (m^3/s) by the input time step for each value bigger than the specified threshold. Discharge volume for an event is registered only when the event initiated in the output period. |
Hydrological Information
Purpose and use of Transformation: |
Measures discharge volume of events in m^3. |
---|---|
Background and Exceptions: |
The input must be m3/s. The output time step must be bigger than the input time step. When subsequent subevents are not interrupted for a period longer than maxGapDistance, the subevents belong to one and the same event. |
Input
description of common and transformation specific input
Options
description of (schema) options to use in this transformation
CoefficientSets
description of connection to CoefficientSets
Output
description of common and transformation specific output
Configuration Example
config example in ready-to-use xml
<Config> Config example in this box for copy & paste </Config>