You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Next »

Information

Transformation:

DischargeVolume

Transformation Group:

Events

Description:

Calculates either the discharge volume of all events initiated in the output period or only the discharge volume of the largest event initiated in the output period. An event in this transformation is defined as a series of subevents where the duration of gaps where there are no subevents is smaller than the specified maxGapDuration parameter. A subevent is defined as a measurement in time in the input where the value is larger than the specified threshold. The discharge volume of a subevent is calculated by multiplying the input value (m3/s) by the duration of the input time step. The discharge volume for an event is registered only in the output period where the event initiated.

Hydrological Information

Purpose and use of Transformation:

Aggregates discharge volume of selected subevents in m3. This transformation can for instance be used to report statistics on sewer spillage.

Background and Exceptions:

The input must be m3/s.

The output time step must be bigger than the input time step. |

Input

description of common and transformation specific input

Options

eventSelection

threshold

maxGapDuration

CoefficientSets

No connection to CoefficientSets.

Output

description of common and transformation specific output

Configuration Example

config example in ready-to-use xml

 
<Config> Config example in this box for copy & paste </Config>
 