Information
Transformation: |
DischargeVolume |
---|---|
Transformation Group: |
Events |
Description: |
Calculates either the discharge volume of all events initiated in the output period or only the discharge volume of the largest event initiated in the output period. |
Hydrological Information
Purpose and use of Transformation: |
Aggregation of discharge volume of events in m3. |
---|---|
Background and Exceptions: |
An event in this transformation is defined as a series of subevents where the duration of gaps where there are no subevents is smaller than the specified maxGapDuration. A subevent is defined a measurement in the input where the value is larger than the specified threshold.The input must be m3/s. The output time step must be bigger than the input time step. When subsequent subevents are not interrupted for a period longer than maxGapDistance, the subevents belong to one and the same event. by multiplying the input value (m3/s) by the duration of the input time step for each subevent. The discharge volume for an event is registered only in the output period where the event initiated. |
Input
description of common and transformation specific input
Options
eventSelection
threshold
maxGapDuration
CoefficientSets
No connection to CoefficientSets.
Output
description of common and transformation specific output
Configuration Example
config example in ready-to-use xml
<Config> Config example in this box for copy & paste </Config>